Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo Images
Top Cited Papers
- 1 March 2018
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 286 (3) , 948-959
Abstract
Dixon T2-weighted fat-only images have the potential to replace T1-weighted images for the detection of spinal bone marrow metastases; the results of this study showed that diagnostic performance with images reconstructed from the Dixon sequence (Dixon T2-weighted fat-only and water-only imaging) was not inferior to that with the standard protocol (T1-weighted and Dixon T2-weighted water-only imaging). PurposeTo test the potential of Dixon T2-weighted fat-only sequences to replace T1-weighted sequences for the detection of bone metastases, with the hypothesis that diagnostic performance with an alternative magnetic resonance (MR) imaging protocol (sagittal spin-echo Dixon T2-weighted fat-only and water-only imaging) would not be inferior to that with the standard protocol (sagittal spin-echo T1-weighted and spin-echo Dixon T2-weighted water-only imaging).Materials and MethodsA total of 121 consecutive whole-spine MR imaging examinations (63 men; mean age ± standard deviation, 61.4 years ± 11.8) performed for suspected vertebral bone metastases were included in this retrospective, institutional review board–approved study. Quantitative image analysis was performed for 30 randomly selected spine levels. Qualitative analysis was performed separately by two musculoskeletal radiologists, who registered the number of metastases for each spine level. Areas under the curve with the protocols were compared on th...Keywords
This publication has 41 references indexed in Scilit:
- MRI for response assessment in metastatic bone diseaseEuropean Radiology, 2013
- MRI of Spinal Bone Marrow: Part 2, T1-Weighted Imaging-Based Differential DiagnosisAmerican Journal of Roentgenology, 2011
- MRI of Spinal Bone Marrow: Part 1, Techniques and Normal Age-Related AppearancesAmerican Journal of Roentgenology, 2011
- Fast spin‐echo triple echo dixon: Initial clinical experience with a novel pulse sequence for simultaneous fat‐suppressed and nonfat‐suppressed T2‐weighted spine magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2011
- Fat and water magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009
- Fast dixon‐based multisequence and multiplanar MRI for whole‐body detection of cancer metastasesJournal of Magnetic Resonance Imaging, 2009
- Dixon techniques for water and fat imagingJournal of Magnetic Resonance Imaging, 2008
- Magnetic Resonance Imaging of the Axial Skeleton for Detecting Bone Metastases in Patients With High-Risk Prostate Cancer: Diagnostic and Cost-Effectiveness and Comparison With Current Detection StrategiesJournal of Clinical Oncology, 2007
- Diagnostic value of MRI in comparison to scintigraphy, PET, MS-CT and PET/CT for the detection of metastases of boneEuropean Journal of Radiology, 2005
- T2‐weighted spine imaging with a fast three‐point dixon technique: Comparison with chemical shift selective fat suppressionJournal of Magnetic Resonance Imaging, 2004