4D Blood Flow Reconstruction Over the Entire Ventricle From Wall Motion and Blood Velocity Derived From Ultrasound Data
Open Access
- 1 May 2015
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (11) , 2298-2308
Abstract
We demonstrate a new method to recover 4D blood flow over the entire ventricle from partial blood velocity measurements using multiple 3D+t colour Doppler images and ventricular wall motion estimated using 3D+t BMode images. We apply our approach to realistic simulated data to ascertain the ability of the method to deal with incomplete data, as typically happens in clinical practice. Experiments using synthetic data show that the use of wall motion improves velocity reconstruction, shows more accurate flow patterns and improves mean accuracy particularly when coverage of the ventricle is poor. The method was applied to patient data from 6 congenital cases, producing results consistent with the simulations. The use of wall motion produced more plausible flow patterns and reduced the reconstruction error in all patients.Keywords
Funding Information
- Wellcome Trust (102431)
- Engineering and Physical Sciences Research Council (EP/H046410/1)
This publication has 21 references indexed in Scilit:
- Temporal sparse free-form deformationsMedical Image Analysis, 2013
- A sensitivity analysis on 3D velocity reconstruction from multiple registered echo Doppler viewsMedical Image Analysis, 2013
- Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2011
- Fluid-solid coupling for the investigation of diastolic and systolic human left ventricular functionInternational Journal for Numerical Methods in Biomedical Engineering, 2010
- Two-Dimensional Intraventricular Flow Mapping by Digital Processing Conventional Color-Doppler Echocardiography ImagesIEEE Transactions on Medical Imaging, 2010
- A New Echocardiographic Method for Identifying Vortex Flow in the Left Ventricle: Numerical ValidationUltrasound in Medicine & Biology, 2010
- Registration of Multiview Real-Time 3-D Echocardiographic SequencesIEEE Transactions on Medical Imaging, 2007
- Full Motion and Flow Field Recovery From Echo Doppler DataIEEE Transactions on Medical Imaging, 2006
- The Medical Imaging Interaction ToolkitMedical Image Analysis, 2005
- Automated ECG segmentation with dynamic time warping2002