Comparison of Peak Cough Flows Measured by Pneumotachograph and a Portable Peak Flow Meter
Authors:
- Emilio ServeraESEmilio Servera
- Juan DíazJDJuan Díaz
- Julio MarínJMJulio Marín
- 1 August 2004
- journal article
- clinical trial
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 83 (8) , 608-612
Abstract
Sancho J, Servera E, Díaz J, Marín J: Comparison of peak cough flows measured by pneumotachograph and a portable peak flow meter. Am J Phys Med Rehabil 2004;83:608–612. To compare peak cough flows (PCF) obtained with a pneumotachograph (PCFp) with those measured using a portable peak flow meter (PCFm) in a population of healthy subjects and patients with neuromuscular disease. A total of 30 healthy subjects and 32 medically stable patients with neuromuscular diseases were studied. Using an oronasal mask connected, in a randomized order, to a pneumotachograph and to a portable peak flow meter, PCFp and PCFm were measured as every subject performed maximal cough efforts from total lung capacity. PCFp measurements were 377.70 ± 179.28 liters/min and PCFm measurements were 377.50 ± 172.98 liters/min (not significant). The two measurements were correlated (r = 0.95, P < 0.001). The random error obtained was 9.37%. The mean of the differences between the values obtained using both instruments ± limits of agreement (+2 SD) was 0.20 ± 109.78 liters/min (not significant). When the agreement was tested over three ranges of flows (480 liters/min), no statistically significant differences were obtained for the population as a whole in any range; however, in the lower flow range, 14 patients had PCFm significantly greater than PCFp (213.93 ± 55.92 vs. 180.86 ± 57.22, P = 270 liters/min. However, some caution must be exercised in clinical practice at lower PCF because of the tendency of this portable device to overestimate the lower flows.Keywords
This publication has 26 references indexed in Scilit:
- Duchenne Muscular DystrophyAmerican Journal of Physical Medicine & Rehabilitation, 2002
- Effect of manually assisted cough and mechanical insufflation on cough flow of normal subjects, patients with chronic obstructive pulmonary disease (COPD), and patients with respiratory muscle weaknessThorax, 2001
- The pleura: the outer space of pulmonary medicineEuropean Respiratory Journal, 1997
- The Accuracy of a Handheld Portable SpirometerChest, 1996
- Comparing MiniWright and Spirometer Measurements of Peak Expiratory FlowChest, 1995
- The accuracy of portable peak flow meters.Thorax, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The dynamics of cough in health and in chronic bronchitis.Thorax, 1967
- COUGH PEAK FLOW HATEThe American Journal of the Medical Sciences, 1966
- MECHANICAL PRODUCTION OF EXPIRATORY FLOW RATES SURPASSING THE CAPACITY OF HUMAN COUGHINGThe American Journal of the Medical Sciences, 1953