Effects of Equipment Dimensions on Circulation Flow Rates of Liquid and Gas in Bubble Column with Draft Tube.
- 1 January 2000
- journal article
- Published by Taylor & Francis in JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
- Vol. 33 (3) , 379-385
Abstract
For a bubble column with draft tube sparging gas into the annulus, the effects of equipment dimensions and liquid properties on the circulation flow rates of liquid and gas are experimentally studied. The gas circulation flow rate is estimated by comparing gas holdup in the downcomer with that in a gas-liquid cocurrent downflow bubble column. The liquid circulation flow rate becomes higher as the distance between the upper end of draft tube and the liquid surface at aeration lengthens, and it remains unchanged when the distance is beyond double the column diameter. It increases with increasing draft tube diameter and with increasing bubble size. The gas circulation flow rate is strongly governed by the liquid circulation flow rate. The driving force for gas circulation is the difference between the descending velocity of liquid and the rising velocity of bubble swarm in the downcomer. Based on the energy balance, an empirical equation of the loss coefficient in the zone above the upper end of the draft tube is obtained. The circulation flow rates of liquid and gas calculated by using the energy balance and correlations, agree with the measured data within an error of ±30%.Keywords
This publication has 9 references indexed in Scilit:
- Flow dynamics in a draft-tube bubble column using various liquidsChemical Engineering Science, 1991
- Recirculation and flow structures of gas in downcomer section of a concentric cylindrical airlift reactorJournal of Chemical Technology & Biotechnology, 1990
- Liquid circulation in airlift reactorsChemical Engineering Science, 1988
- Flow characteristics in three-phase fluidized bed with draft tube.KAGAKU KOGAKU RONBUNSHU, 1987
- Mixing and mass transfer in concentric‐tube airlift fermenters: Newtonian and non‐newtonian mediaJournal of Chemical Technology & Biotechnology, 1986
- Air‐lift reactor analysis: Interrelationships between riser, downcomer, and gas‐liquid separator behavior, including gas recirculation effectsAIChE Journal, 1986
- Liquid circulation in a draft-tube bubble columnChemical Engineering Science, 1985
- Liquid circulation, gas holdup and pressure drop in bubble column with draught tube.JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1984
- Average Volumetric Concentration in Two-Phase Flow SystemsJournal of Heat Transfer, 1965