Comparison of vault after implantation of posterior chamber phakic intraocular lens with and without a central hole
Authors:
- 1 January 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 41 (1) , 67-72
Abstract
To compare the vault after implantation of a posterior chamber phakic intraocular lens (pIOL) (Visian Implantable Collamer Lens) with and without a central artificial hole for moderate to high ametropia. Department of Ophthalmology, Kitasato University, Kanagawa, Japan. Retrospective comparative study. The study comprised eyes of patients who had central hole pIOL implantation in 1 eye and conventional pIOL implantation in the fellow eye. The time course of the postoperative pIOL vault was quantitatively assessed using a rotating Scheimpflug camera (Pentacam HR). Twenty-three patients (46 eyes) (mean age 31.3 years ± 7.4 [SD]) were enrolled in the study. The amount of vault with the central hole pIOL was 603 ± 276 μm, 552 ± 261 μm, 539 ± 258 μm, 520 ± 240 μm, and 482 ± 245 μm, at 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively, respectively. The amount with the conventional pIOL vault was 585 ± 252 μm, 550 ± 269 μm, 514 ± 253 μm, 485 ± 233 μm, and 459 ± 239 μm, respectively. There was no significant association between the pIOL vault and the refractive accuracy 1 year postoperatively (Spearman correlation coefficient r = 0.18, P = 0.41 for central hole pIOL and r = 0.07, P = .76 for conventional pIOL). The vault of the new central hole pIOL appeared to be essentially equivalent to the vault of the conventional pIOL, suggesting that the presence of the central hole did not significantly affect the vault or the refractive accuracy. Dr. Shimizu is a consultant to Staar Surgical Co. and has assisted with the development of patented technologies. No other author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 23 references indexed in Scilit:
- Intraindividual Comparison of Visual Performance After Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole Implantation for Moderate to High MyopiaAmerican Journal of Ophthalmology, 2012
- Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforationGraefe's Archive for Clinical and Experimental Ophthalmology, 2011
- Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-upJournal of Cataract & Refractive Surgery, 2011
- Modulation transfer function of intraocular collamer lens with a central artificial holeGraefe's Archive for Clinical and Experimental Ophthalmology, 2011
- One-Year Follow-up of Posterior Chamber Toric Phakic Intraocular Lens Implantation for Moderate to High Myopic AstigmatismOphthalmology, 2010
- Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatismJournal of Cataract & Refractive Surgery, 2010
- Crystalline lens changes in porcine eyes with implanted phakic IOL (ICL) with a central holeGraefe's Archive for Clinical and Experimental Ophthalmology, 2008
- Toric Implantable Collamer Lens for Moderate to High Myopic AstigmatismOphthalmology, 2007
- Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eyeGraefe's Archive for Clinical and Experimental Ophthalmology, 2006
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004