Accuracy and reproducibility of left ventricular outflow tract diameter measurement using transthoracic when compared with transesophageal echocardiography in systole and diastole
Authors:
- A. ShiranASA. Shiran
- S. AdawiSAS. Adawi
- M. GanaeemMGM. Ganaeem
- E. AsmerEAE. Asmer
- 4 August 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 10 (2) , 319-324
Abstract
Accurate measurement of left ventricular outflow tract diameter (LVOTd) is essential for reliable estimation of aortic valve area (AVA) using the continuity equation. Transesophageal echocardiography (TEE) can accurately delineate the LVOT. The aim of this study was to assess the accuracy and reproducibility of LVOTd measurement using transthoracic echocardiography (TTE) with harmonic imaging when compared with TEE, in both systole and diastole. We prospectively studied 50 patients [20 with aortic stenosis (AS) and 30 without AS]. LVOTd was measured offline in a blinded fashion in both systole and diastole by two experienced observers using TTE in the parasternal long axis view and TEE in the mid-oesophageal aortic view ( approximately 130 degrees ). There was strong correlation between TTE and TEE (r=0.91). LVOTd was slightly smaller by TTE when compared with TEE (2.11+/-0.21 vs. 2.16+/-0.22 cm, mean difference -0.05+/-0.09 cm, P=0.0003). Compared with TEE, 95% (2SD) of LVOTd measurements by TTE were within +0.14 and -0.24 cm. Inter- and intra-observer variability for LVOTd was 4.8+/-4.1 and 2.8+/-1.9% for TTE and 4.2+/-3.1 and 2.5+/-1.6% for TEE (P=0.4 and 0.6). In patients with AS, estimated AVA was 0.93+/-0.22 cm(2) using TTE and 0.96+/-0.24 cm(2) using TEE, P=0.08. Diastolic LVOTd by TEE was slightly smaller compared with systolic LVOTd by TEE (-0.03+/-0.07 cm, P=0.0005), and there was strong correlation between the two (r=0.95). We present the data regarding accuracy and reproducibility of LVOTd measurements by TTE when compared with TEE. LVOTd measurements at end-diastole may be helpful when systolic images are suboptimal.Keywords
This publication has 20 references indexed in Scilit:
- Value of multiplane transesophageal echocardiography in determining aortic valve area in aortic stenosisThe American Journal of Cardiology, 1996
- Quantitation of aortic valve area in aortic stenosis with multiplane transesophageal echocardiography: Comparison with monoplane transesophageal approachAmerican Heart Journal, 1994
- Reproducibility of Doppler echocardiographic quantification of aortic and mitral valve stenoses: Comparison between two echocardiography centersThe American Journal of Cardiology, 1991
- Prediction of the severity of aortic stenosis by Doppler aortic valve area determination: Prospective Doppler-catheterization correlation in 100 patientsJACC, 1988
- A practical application of Doppler echocardiography for the assessment of severity of aortic stenosisAmerican Heart Journal, 1988
- Pivotal role of aortic valve area calculation by the continuity equation for Doppler assessment of aortic stenosis in patients with combined aortic stenosis and regurgitationThe American Journal of Cardiology, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography.Circulation, 1985
- Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula.Circulation, 1985
- Determination of cardiac output by Doppler echocardiography.Heart, 1984