A surface EMG test tool to measure proportional prosthetic control
Authors:
- Agnes SturmaASAgnes Sturma
- Aidan D. RocheARAidan D. Roche
- Peter GöbelPGPeter Göbel
- Malvina HercegMHMalvina Herceg
- Nan GeNGNan Ge
- Veronika Fialka-MoserVFVeronika Fialka-Moser
- Oskar AszmannOAOskar Aszmann
- 1 January 2015
- journal article
- research article
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 60 (3) , 207-213
Abstract
In upper limb amputees, prosthetic control training is recommended before and after fitting. During rehabilitation, the focus is on selective proportional control signals. For functional monitoring, many different tests are available. None can be used in the early phase of training. However, an early assessment is needed to judge if a patient has the potential to control a certain prosthetic set-up. This early analysis will determine if further training is needed or if other strategies would be more appropriate. Presented here is a tool that is capable of predicting achievable function in voluntary EMG control. This tool is applicable to individual muscle groups to support preparation of training and fitting. In four of five patients, the sEMG test tool accurately predicted the suitability for further myoelectric training based on SHAP outcome measures. (P1: “Poor” function in the sEMG test tool corresponded to 54/100 in the SHAP test; P2: Good: 85; P3: Good: 81; P4: Average: 78). One patient scored well during sEMG testing, but was unmotivated during SHAP testing. (Good: 50) Therefore, the surface EMG test tool may predict achievable control skills to a high extent, validated with the SHAP, but requires further clinical testing to validate this technique.Keywords
This publication has 14 references indexed in Scilit:
- Prosthetic Myoelectric Control Strategies: A Clinical PerspectiveCurrent Surgery Reports, 2014
- Determining skill level in myoelectric prosthesis use with multiple outcome measuresJournal of Rehabilitation Research and Development, 2012
- Responsiveness and validity of three dexterous function measures in stroke rehabilitationJournal of Rehabilitation Research and Development, 2010
- Investigating latent constructs with item response models: A MATLAB IRTm toolboxBehavior Research Methods, 2009
- Case Studies to Demonstrate the Range of Applications of the Southampton Hand Assessment ProcedureBritish Journal of Occupational Therapy, 2009
- Assessment of capacity for myoelectric control: Evaluation of construct and rating scaleJournal of Rehabilitation Medicine, 2009
- INTRA- AND INTER-RATER RELIABILITY OF THE ASSESSMENT OF CAPACITY FOR MYOELECTRIC CONTROLJournal of Rehabilitation Medicine, 2006
- Critical Factors in Electrically Powered Upper-Extremity ProstheticsJPO Journal of Prosthetics and Orthotics, 2002
- Rehabilitation in limb deficiency. 4. Limb amputationArchives of Physical Medicine and Rehabilitation, 1996
- A performance test for assessment of upper limb function in physical rehabilitation treatment and researchInternational Journal of Rehabilitation Research, 1981