STUDYING THE ELECTROCHEMICAL BEHAVIORS OF ANODIZED METALLIC IMPLANTS FOR IMPROVED CORROSION RESISTANCE
Open Access
- 28 June 2022
- journal article
- research article
- Published by Istanbul Ticaret Universitesi in İstanbul Ticaret Üniversitesi Fen Bilimleri Dergisi
- Vol. 21 (41) , 117-135
Abstract
A study about long-term corrosion behavior of anodized and non-anodized Ti6Al4V and MgAZ31B biomaterials was conducted under controlled conditions. By applying 20V DC potential, MgAZ31B alloys was anodized in phosphoric acid and potassium hydroxide while Ti6Al4V alloys was anodized in phosphoric acid and oxalic acid. Long-term experiments were carried out by immersing them in deionized (DI) water, 3% NaCl and phosphate-buffered saline (PBS) solutions. The corrosion rate and pattern were measured by electrochemical analysis. Also, as a result of anodization, the natural oxide layer was observed on the material surface, thus the corrosion rate is reduced and the life of the biomaterial has been improved.Keywords
Funding Information
- Wichita State University
This publication has 52 references indexed in Scilit:
- Biomedical Implants: Corrosion and its Prevention - A ReviewRecent Patents on Corrosion Science, 2010
- Revolutionizing biodegradable metalsMaterials Today, 2009
- Degradable biomaterials based on magnesium corrosionCurrent Opinion in Solid State and Materials Science, 2008
- Progress and Challenge for Magnesium Alloys as BiomaterialsAdvanced Engineering Materials, 2008
- Surface characteristics of AZ91D alloy anodized with various conditionsSurface and Interface Analysis, 2008
- Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological mediaBiomaterials, 2006
- Effects of formation voltage and electrolyte ions concentration on the structure and passivity of anodic films on magnesiumJournal of Japan Institute of Light Metals, 2004
- Implant Applications of Highly Corrosion-Resistant Ti-15Zr-4Nb-4Ta AlloyMATERIALS TRANSACTIONS, 2002
- Processing of biocompatible porous Ti and MgScripta Materialia, 2001
- Crevice Corrosion of Cemented Titanium Alloy Stems in Total Hip ReplacementsClinical Orthopaedics and Related Research, 1996