Forced oscillation assessment of respiratory mechanics in ventilated patients
Open Access
- 1 January 2001
- journal article
- review article
- Published by Springer Nature in Critical Care
- Vol. 5 (1) , 3-9
Abstract
The forced oscillation technique (FOT) is a method for non-invasively assessing respiratory mechanics that is applicable both in paralysed and non-paralysed patients. As the FOT requires a minimal modification of the conventional ventilation setting and does not interfere with the ventilation protocol, the technique is potentially useful to monitor patient mechanics during invasive and noninvasive ventilation. FOT allows the assessment of the respiratory system linearity by measuring resistance and reactance at different lung volumes or end-expiratory pressures. Moreover, FOT allows the physician to track the changes in patient mechanics along the ventilation cycle. Applying FOT at different frequencies may allow the physician to interpret patient mechanics in terms of models with pathophysiological interest. The current methodological and technical experience make possible the implementation of portable and compact computerised FOT systems specifically addressed to its application in the mechanical ventilation setting.Keywords
This publication has 25 references indexed in Scilit:
- Noninvasive assessment of respiratory resistance in severe chronic respiratory patients with nasal CPAPEuropean Respiratory Journal, 2000
- Forced oscillation total respiratory resistance and spontaneous breathing lung resistance in COPD patientsEuropean Respiratory Journal, 1999
- Assessment of Airflow Obstruction during CPAP by Means of Forced Oscillation in Patients with Sleep ApneaAmerican Journal of Respiratory and Critical Care Medicine, 1998
- Analog circuit for real-time computation of respiratory mechanical impedance in sleep studiesIEEE Transactions on Biomedical Engineering, 1997
- Expiratory flow limitation during mechanical ventilation detected by the forced oscillation methodEuropean Respiratory Journal, 1996
- Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levelsEuropean Respiratory Journal, 1995
- Pseudorandom signals to estimate apparent transfer and coherence functions of nonlinear systems: applications to respiratory mechanicsIEEE Transactions on Biomedical Engineering, 1992
- Monte Carlo calculation of temperature dependence of the transport properties in compensated GaAsJournal of Applied Physics, 1991
- A correction procedure for the asymmetry of differential pressure transducers in respiratory impedance measurementsIEEE Transactions on Biomedical Engineering, 1989