The effects of Er:YAG, Nd:YAG, and Diode (940nm) Lasers irradiation on Microtensile bond strength of two steps self-etch adhesives
Authors:
Open Access
- 1 January 2019
- journal article
- Published by PAGEPress Publications in Laser Therapy
- Vol. 28 (2) , 131-137
Abstract
Background and aims: Nowadays, studies show the effective laser irradiation role on the adhesion of bonding agents to the dentin. Therefore, the present study was set to find an appropriate protocol for the use of Nd:YAG, Er:YAG, and Diode lasers during the application of two steps self-etch adhesives in direct dental restorations in order to achieve higher microtensile strength. Materials and methods: A total number of 100 extracted healthy teeth were selected. After removing occlusal enamel and exposing dentin, samples randomly divided into ten groups: Group Control (C), two steps self-etch adhesives was applied in accordance with the manufacturer instructions, without using laser systems; Groups Er-YAG, laser (2940 nm, 10 Hz, 0.4w, 40 mJ) irradiated Before applying Primer (Er-BPsubgroup), After applying Primer (Er-AP subgroup), After applying Bonding (Er-AB subgroup); Groups Nd-YAG, laser (1064 nm, 10 Hz, 1.2w, 40 mJ) irradiated Before applying Primer (Nd-BP subgroup), After applying Primer (Nd-AP subgroup), After applying Bonding (Nd-AB subgroup); Groups Diode, laser (940nm, 10 Hz, 0.7w, 70 mJ) irradiated Before applying Primer (D-BP subgroup), After applying Primer (D-AP subgroup), After applying Bonding (D-AB subgroup). After intervention and composite build up, the samples were stored 24 hours in 37°C distilled water. The microtensile strength was measured using the universal testing machine. The data were analyzed by one-way ANOVA test and post hoc Tukey test. (p < 0.05) Results: The Means and standard deviations of the groups were as follow: C = 30.09 ± 4.21, Er-BP = 18.83± 4.21, Er-AP = 14.43 ± 3.12, Er-AB = 19.67 ± 4.96, Nd-BP = 20.35 ± 5.55, Nd-AP = 39.85 ± 4.13, Nd-AB =18.16 ± 3.36, D-BP = 26.74 ± 5.05, D-AP = 28.11 ± 5.12, D-AB = 37.28 ± 5.61. The mean microtensile strength achieved in groups: Nd-AP and D-AB were significantly higher than control group (p < 0.05).Groups D-BP and D-AP had no significant difference in comparison with control group while the remaining groups had significantly lower values (P < 0.05). Conclusions: Nd:YAG laser irradiation after applying the primer, and diode laser irradiation after applying the bonding agent, both can improve the microtensile bond strength in two steps self-etch adhesive systems significantly.Keywords
This publication has 27 references indexed in Scilit:
- Effect of the clinical application of the diode laser (810 nm) in the treatment of dentine hypersensitivityBMC Research Notes, 2014
- Morphology of resin–dentin interfaces after Er,Cr:YSGG laser and acid etching preparation and application of different bonding systemsLasers in Medical Science, 2011
- Microtensile bond strength of an etch-and-rinse adhesive to enamel and dentin after Er:YAG laser pretreatment with different pulse durationsLasers in Medical Science, 2010
- Assessment of the penetration depth of dental adhesives through deproteinized acid-etched dentin using neodymium:yttrium–aluminum–garnet laser and sodium hypochloriteLasers in Medical Science, 2008
- Shear bond strength of composite bonded to erbium:yttrium-aluminum-garnet laser-prepared dentinLasers in Medical Science, 2007
- Influence of Nd:YAG Laser Irradiation on an Adhesive Restorative ProcedureOperative Dentistry, 2006
- Influence of Er:YAG laser on tensile bond strength of a self-etching system and a flowable resin in different dentin depthsJournal of Dentistry, 2004
- Effect of Er:YAG laser on bond strength to dentin of a self‐etching primer and two single‐bottle adhesive systemsLasers in Surgery and Medicine, 2002
- Avaliação morfológica da união entre adesivo/resina composta e dentina irradiada com laser Er:YAG e laser Nd:YAG: estudo comparativo por microscopia de varreduraPesquisa Odontológica Brasileira, 2001
- Microtensile bond strengths of seven dentin adhesive systemsDental Materials, 2000