Six-Component (6C) Motions in a 50-Story Skyscraper in Kunming, Yunnan Province, China, Recorded During the Mw 7.7 Mandalay, Myanmar, Earthquake of 28 March 2025: What Caused the Beating in the Response?
- 10 July 2026
- journal article
- Published by Seismological Society of America (SSA) in Seismological Research Letters
Abstract
The Mw 7.7 Mandalay, Myanmar, earthquake of 28 March 2025 caused devastation in Myanmar and severe damage to structures as far as Bangkok, 700 km away from the fault. The mainshock was followed 11 min later by a powerful Mw 6.7 aftershock, both of which were recorded in a densely instrumented 50-story skyscraper located in Kunming, Yunnan Province, China, 773 km northeast from the epicenter. While the ground motion at the building site and the structural response were small (∼10−4 rad peak interstory drift), the building vibration exhibited long duration (about 24 min) and beating, which was the most regular and persistent in the transverse response. Beating, observed in earthquake response of tall buildings, has been previously attributed to coupling of modal responses with close but not identical frequencies or of modal response(s) with a site resonance of similar frequency. In this article, it is shown for the first time that beating can be caused also by the input ground motion. The beating in the transverse response was caused by coupling of the fundamental transverse mode (fN,1=0.267 Hz) with narrowband energy in the ground motion (fg=0.235 Hz) carried to the site by surface waves, which resulted in beats of length TB=1/|fg−fN,1|≈31 s. The beating in the torsional response was caused by coupling of the fundamental torsional (fT,1=0.353 Hz) and longitudinal (fE,1=0.377 Hz) modal responses, resulting in beats of length TB=1/|fT,1−fE,1|≈41.7 s. Beating in the response of tall buildings during distant earthquakes is of concern because it amplifies the peak response of the lightly damped structure, which, combined with long duration, may cause fatigue and, upon repeated exposures, reduce its capacity to resist earthquakes.Keywords
This publication has 17 references indexed in Scilit:
- Recorded responses of Four Tall buildings in South China to the M 7.9 Myanmar Earthquake on March 28, 2025Earthquake Research Advances, 2025
- Comparative study of seismic responses of an instrumented tall building in Dali, Yunnan from the distant Myanmar Mw 7.7 earthquake and the local Yangbi moderate earthquakesStructures, 2025
- Assessment of seismic intensity and seismic performance of buildings in the M7.9 Myanmar earthquakeEarthquake Engineering and Engineering Vibration, 2025
- In the wake of the March 28, 2025 Myanmar earthquake: A detailed examinationJournal of Dynamic Disasters, 2025
- Data‐Driven Models for Prediction of the Modal Frequencies Drift and Fluctuations as Function of the Environmental Conditions for a 50‐Story Skyscraper in a Seismic RegionEarthquake Engineering & Structural Dynamics, 2025
- Field survey of building damage at Mandalay during 2025 Myanmar Mw 7.7 earthquakeEarthquake Engineering and Engineering Vibration, 2025
- The role of the foundation flexibility on the seismic response of a modern tall building: Vertically incident plane wavesSoil Dynamics and Earthquake Engineering, 2024
- Tongde Plaza Yue Center (TPYC) Full-Scale Testbed Site: Fixed-Base Digital Twin and Its Validation Using Microtremors2023
- A new full‐scale testbed for structural health monitoring and soil–structure interaction studies: Kunming 48‐story office building in Yunnan province, ChinaStructural Control and Health Monitoring, 2020
- Response of a tall building far from the epicenter of the 11 March 2011 M 9.0 Great East Japan earthquake and aftershocksThe Structural Design of Tall and Special Buildings, 2012