Variability of office, 24-hour ambulatory, and self-monitored blood pressure measurements
Authors:
- Roderick E WarrenRWRoderick E Warren
- Tom MarshallTMTom Marshall
- Paul L PadfieldPPPaul L Padfield
- Sigrun ChrubasikSCSigrun Chrubasik
Open Access
- 1 September 2010
- journal article
- Published by Royal College of General Practitioners in British Journal of General Practice
- Vol. 60 (578) , 675-680
Abstract
The diagnosis of hypertension is difficult when faced with several different blood pressure measurements in an individual. Using the average of several office measurements is recommended, although considerable uncertainty remains. Twenty-four-hour ambulatory monitoring is often considered the gold standard, but self-monitoring of blood pressure has been proposed as a superior method. Determination of within-individual variability of blood pressure measured in the office, by ambulatory monitoring, and by a week of self-monitoring. Retrospective analysis of a clinical trial of 163 subjects. Within-patient variability of office and ambulatory blood pressure was determined from measurements at 0 and 6 weeks. Subjects had performed self-monitoring of blood pressure twice each morning and evening, for at least 6 weeks; variability was determined from the means of week 1 and week 6. The within-individual coefficients of variation (CVs) for systolic blood pressure were: office, 8.6%; ambulatory, 5.5%; self, 4.2%. Equivalent values for diastolic blood pressure were 8.6%, 4.9%, and 3.9%. CVs tended to be lower with longer self-monitoring duration, and higher with longer intervals between self-monitoring. Office blood pressure is impractical for precise assessment, as 10-13 measurements are required to give the accuracy required for rational titration of antihypertensive drugs. Twenty-four-hour ambulatory monitoring is better than a single office measurement, but considerable uncertainty remains around the estimate. A week of self-monitoring appears to be the most accurate method of measuring blood pressure, but remains imperfect. Further research may identify superior self-monitoring schedules. Given the inherent accuracy in blood pressure measurement, the importance of considering overall cardiovascular risk is emphasised.Keywords
This publication has 14 references indexed in Scilit:
- Blood Pressure Variability: The Challenge of VariationAmerican Journal of Hypertension, 2008
- Comparison of different methods of blood pressure measurementsBlood Pressure Monitoring, 2007
- JBS 2: Joint British Societies' guidelines on prevention of cardiovascular disease in clinical practiceHeart, 2005
- Value of low dose combination treatment with blood pressure lowering drugs: analysis of 354 randomised trialsBMJ, 2003
- How should we measure blood pressure in the doctorʼs office?Blood Pressure Monitoring, 2001
- Reproducibility of ambulatory blood pressure monitoring in hemodialysis patientsAmerican Journal of Kidney Diseases, 2000
- Is a Series of Blood Pressure Measurements by the General Practitioner or the Patient a Reliable Alternative to Ambulatory Blood Pressure Measurement? A Study in General Practice With Reference to Short-term and Long-term Between-Visit VariabilityAmerican Journal of Hypertension, 1997
- Hemodynamic Patterns of Age-Related Changes in Blood PressureCirculation, 1997
- Statistics Notes: Measurement error proportional to the meanBMJ, 1996
- MRC trial of treatment of mild hypertension: principal results. Medical Research Council Working Party.BMJ, 1985