New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
Open Access
Abstract
Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from abusive use is not conclusive, and the cut-off value for biological samples has not been established. Herein, new cost-effective and robust all-solid-state platforms based on potentiometric transduction were fabricated and successfully utilized for caffeine assessment. The platforms were modified with reduced graphene oxide (rGO). Tailored caffeine-imprinted polymeric beads (MIPs) based on methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were prepared, characterized, and used as recognition receptors in the presented potentiometric sensing devices. In 50 mM MES buffer, the sensors exhibited a slope response of 51.2 ± 0.9 mV/decade (n = 6, R2 = 0.997) over the linear range of 4.5 × 10−6–1.0 × 10−3 M with a detection limit of 3.0 × 10−6 M. They exhibited fast detection of caffeinium ions with less than 5 s response time (<5 s). The behavior of the presented sensors towards caffeinium ions over many common organic and inorganic cations was evaluated using the modified separate solution method (MSSM). Inter-day and intra-day precision for the presented analytical device was also evaluated. Successful applications of the presented caffeine sensors for caffeine determination in commercial tea and coffee and different pharmaceutical formulations were carried out. The data obtained were compared with those obtained by the standard liquid chromatographic approach. The presented analytical device can be considered an attractive tool for caffeine determination because of its affordability and vast availability, particularly when combined with potentiometric detection.Keywords
Funding Information
- Deanship of Scientific Research, King Saud University (RGP.1/286/42)
This publication has 65 references indexed in Scilit:
- FIA potentiometric system based on periodate polymeric membrane sensors for the assessment of ascorbic acid in commercial drinksFood Chemistry, 2010
- Potentiometric Sensing of Neutral Species Based on a Uniform‐Sized Molecularly Imprinted Polymer as a ReceptorAngewandte Chemie International Edition, 2010
- Flow‐Through Assay of Quinine Using Solid Contact Potentiometric Sensors Based on Molecularly Imprinted PolymersElectroanalysis, 2009
- Clinical importance of caffeine dependence and abusePsychiatry and Clinical Neurosciences, 2007
- Capillary electrophoresis for caffeine and pyroglutamate determination in coffeesJournal of Pharmaceutical and Biomedical Analysis, 2006
- Novel Biomedical Sensors for Flow Injection Potentiometric Determination of Creatinine in Human SerumElectroanalysis, 2005
- Food sources and intakes of caffeine in the diets of persons in the United StatesJournal of the American Dietetic Association, 2005
- The Measurement of Caffeine Concentration in Scalp Hair as an Indicator of Liver FunctionJournal of Pharmacy and Pharmacology, 1996
- Determination of Improved Selectivity Coefficients of Polymer Membrane Ion‐Selective Electrodes by Conditioning with a Discriminated IonJournal of the Electrochemical Society, 1996
- Fluorometric reactions of purines and determination of caffeineTalanta, 1989