Abstract
In this work, we present a systematic study of the effects of annealing on the thermoluminescence (TL) properties of well-sintered scandium oxide (Sc2O3) pellets. Samples weighing 60 mg were annealed at temperatures ranging from 700 to 1600 °C in air for durations of 1 to 50 hours, and their key TL characteristics were evaluated. A clear trend was observed: the TL response increased with increasing annealing time and temperature, enabling the selection of specific samples for detailed analysis of reproducibility, kinetic parameters, and TL fading. The results demonstrate that the thermoluminescent properties of Sc₂O₃ can be significantly enhanced through tailored thermal treatments, improving aspects such as the shape of glow curves (including peak positions and full width at half maximum of main peaks), reproducibility across multiple uses, and the stability of the TL signal after irradiation with beta particles.

This publication has 21 references indexed in Scilit: