Triple repetition time saturation transfer (TRiST) 31P spectroscopy for measuring human creatine kinase reaction kinetics
Authors:
Open Access
- 4 May 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (6) , 1493-1501
Abstract
Human cardiac phosphorus MR saturation transfer experiments to quantify creatine kinase forward rate constants (kf) have previously been performed at 1.5 T. Such experiments could benefit from increased signal‐to‐noise ratio (SNR) and spectral resolution at 3 T. At 1.5 T, the four‐angle saturation transfer method was applied with low‐angle adiabatic pulses and surface coils. However, low‐angle adiabatic pulses are potentially problematic above 1.5 T due to bandwidth limitations, power requirements, power deposition, and intrapulse spin‐spin relaxation. For localized metabolite spin‐lattice relaxation time (T1) measurements, a dual repetition time approach with adiabatic half‐passage pulses was recently introduced to solve these problems at 3 T. Because the saturation transfer experiment requires a T1 measurement performed while one reacting moiety is saturated, we adapt the dual repetition time approach to measure kf using a triple repetition time saturation transfer (TRiST) method. A new pulsed saturation scheme with reduced sensitivity to static magnetic field inhomogeneity and compatibility with cardiac triggering is also presented. TRiST measurements of kf are validated in human calf muscle against conventional saturation transfer and found to agree within 3%. The first 3‐T TRiST measurements of creatine kinase kf in the human calf (n = 6), chest muscle, and heart (n = 8) are 0.26 ± 0.04 s−1, 0.23 ± 0.03 s−1, and 0.32 ± 0.07 s−1, respectively, consistent with prior 1.5 T values. Magn Reson Med, 2010.Keywords
Funding Information
- NIH (R01 HL56882, R01 HL61912)
- D.W. Reynolds Foundation
This publication has 35 references indexed in Scilit:
- Novel strategy for measuring creatine kinase reaction rate in the in vivo heartAmerican Journal of Physiology-Heart and Circulatory Physiology, 2009
- Reduced Myocardial Creatine Kinase Flux in Human Myocardial InfarctionCirculation, 2009
- Quantitative cardiac 31P spectroscopy at 3 Tesla using adiabatic pulsesMagnetic Resonance in Medicine, 2009
- Quantitative ATP synthesis in human liver measured by localized 31P spectroscopy using the magnetization transfer experimentNMR in Biomedicine, 2008
- Correcting reaction rates measured by saturation-transfer magnetic resonance spectroscopyJournal of Magnetic Resonance, 2008
- Altered Creatine Kinase Adenosine Triphosphate Kinetics in Failing Hypertrophied Human MyocardiumCirculation, 2006
- Mapping creatine kinase reaction rates in human brain and heart with 4 tesla saturation transfer 31P NMRJournal of Magnetic Resonance (1969), 1992
- Symmetric pulses to induce arbitrary flip angles with compensation for rf inhomogeneity and resonance offsetsJournal of Magnetic Resonance (1969), 1991
- A simple pulse sequence for selective excitation in Fourier transform NMRJournal of Magnetic Resonance (1969), 1976
- Study of Moderately Rapid Chemical Exchange Reactions by Means of Nuclear Magnetic Double ResonanceThe Journal of Chemical Physics, 1963