Dynamic behavior of respiratory system during nasal continuous positive airway pressure in spontaneously breathing premature newborn infants
Authors:
- 21 April 2004
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 37 (6) , 485-491
Abstract
The end‐expiratory lung‐volume level of premature newborn infants is maintained above passive resting volume during active breathing, through the combination of reduced time constant and high respiratory rate. To determine whether nasal continuous positive airway pressure (NCPAP) alters this characteristic dynamic breathing pattern, we studied the effects of various NCPAP levels on the dynamic elevation of end‐expiratory lung volume level (ΔEELV) in spontaneously breathing premature newborn infants, using respiratory inductive plethysmography (RIP). Eleven premature newborn infants with moderate respiratory failure were included. NCPAP levels were set in a random order to 0, 2, 4, and 6 cm H2O. Tidal volume (Vt), rib‐cage contribution to Vt (%RC), phase angle between abdominal and thoracic motions (θ), respiratory rate (RR), and inspiratory and expiratory times (Ti and Te) were continuously recorded by RIP. The slope of the linear part of the expiratory flow‐volume relation was extrapolated up to zero flow level to evaluate the dynamic elevation of the functional residual capacity (FRC) (ΔEELV). The time‐constant of the respiratory system (τRS) was calculated as the slope of the linear part of the expiratory flow‐volume loop. At NCPAP = 6 cm H2O, ΔEELV reached 0.6 ± 0.2 times the Vt at NCPAP = 0 cm H2O. An increase in NCPAP level resulted in a significant decrease in ΔEELV (P < 0.01). A decrease in ΔEELV during NCPAP was associated with a significant increase in Te from 0.62 ± 0.13 sec at NCPAP = 0 cm H2O to 0.80 ± 0.07 sec at NCPAP = 6 cm H2O (P < 0.05), and a decrease in τRSfrom 0.4 ± 0.1 sec at NCPAP = 0 cm H2O to 0.24 ± 0.04 sec at NCPAP = 6 cm H2O (P < 0.01). These results indicate that the characteristic spontaneous breathing pattern causing a dynamic elevation of FRC is abolished by NCPAP. We speculate that the dynamic volume‐preserving mechanisms resulting from expiratory flow braking are no longer required during NCPAP, as the constant pressure may passively elevate FRC. Pediatr Pulmonol. 2004; 37:485–491.Keywords
This publication has 20 references indexed in Scilit:
- Effects of nasal continuous positive airway pressure (NCPAP) on breathing pattern in spontaneously breathing premature newborn infantsIntensive Care Medicine, 2001
- Work of Breathing During Constant- and Variable-Flow Nasal Continuous Positive Airway Pressure in Preterm NeonatesPediatrics, 2001
- Lung Recruitment and Breathing Pattern During Variable Versus Continuous Flow Nasal Continuous Positive Airway Pressure in Premature Infants: An Evaluation of Three DevicesPediatrics, 2001
- Comparison of four methods for measuring elevation of FRC in mechanically ventilated infantsIntensive Care Medicine, 1999
- Nasal Continuous Positive Airway Pressure and Early Surfactant Therapy for Respiratory Distress Syndrome in Newborns of Less Than 30 Weeks' GestationPediatrics, 1999
- Effect of nasal CPAP on thoracoabdominal motion in neonates with respiratory insufficiencyPediatric Pulmonology, 1991
- Effects of nasal CPAP on supraglottic and total pulmonary resistance in preterm infantsJournal of Applied Physiology, 1990
- Continuous positive airway pressure selectively reduces obstructive apnea in preterm infantsThe Journal of Pediatrics, 1985
- Predicted Values for Clinical Exercise TestingAmerican Review of Respiratory Disease, 1984