Abstract
Background: Surgeons experience physical and mental fatigue during prolonged standing. Wearable chairs may reduce fatigue, but clinical evidence remains limited. Objective: To evaluate wearable chair effects on surgeon fatigue during laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair. Methods: Twelve patients undergoing elective TAPP repair were randomized to wearable chair or control groups (n = 6 each). The primary endpoint was the intraoperative low-frequency/high-frequency (LF/HF) ratio derived from heart rate variability. Secondary endpoints included visual analog scale (VAS) assessments and surgical outcomes. Results: No statistically significant between-group difference was detected in the primary LF/HF ratio ( p = 0.485). Subjective physical fatigue was significantly lower in the wearable chair group ( p = 0.045). Mental fatigue, comfort, and surgical maneuverability showed no significant differences ( p = 0.065, 0.054, and 0.066, respectively). Surgical duration, blood loss, postoperative hospital stay, and complication rates showed no significant differences ( p = 0.423, 0.345, 0.091, and 1.000, respectively). Conclusion: In this small exploratory pilot study, a wearable chair may reduce subjective physical fatigue, a secondary outcome, although no statistically significant difference was detected in the primary LF/HF endpoint. Larger multicenter studies are needed to confirm these preliminary findings. Trial registration: UMIN-CTR (UMIN000057932)