Energy and Cost Associated with Ventilating Office Buildings in a Tropical Climate
Open Access
- 30 March 2015
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (3) , e0122310
Abstract
Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person), indoor air temperature and humidity, air conditioning system coefficient of performance (COP), and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore’s tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person) at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore’s. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person — which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave — can be much larger than the incremental cost of ventilation.Keywords
This publication has 41 references indexed in Scilit:
- Quantitative relationships between occupant satisfaction and satisfaction aspects of indoor environmental quality and building designIndoor Air, 2011
- Benefits and costs of improved IEQ in U.S. officesIndoor Air, 2011
- Energy consumption, energy savings, and emission analysis in Malaysian office buildingsEnergy Policy, 2009
- Quantitative relationship of sick building syndrome symptoms with ventilation ratesIndoor Air, 2009
- Sensitivity analysis and energy conservation measures implicationsEnergy Conversion and Management, 2008
- Building energy efficiency labeling programme in SingaporeEnergy Policy, 2008
- Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: the US EPA BASE studyIndoor Air, 2008
- Ventilation and performance in office workIndoor Air, 2006
- Organic compounds in office environments - sensory irritation, odor, measurements and the role of reactive chemistryIndoor Air, 2006
- Building-Related IllnessesNew England Journal of Medicine, 1997