High-sensitivity absorption spectroscopy on a microwave plasma-assisted chemical vapour deposition diamond growth facility

Authors:
  • CEC J Erickson
    C J Erickson
  • WJW B Jameson
    W B Jameson
  • KMK L Menningen
    K L Menningen
  • MCM A Childs
    M A Childs
  • JLJ E Lawler
    J E Lawler

Abstract
High-sensitivity absorption spectroscopy using a multi-element detector was performed on a microwave plasma-assisted chemical vapour deposition (MPACVD) diamond growth facility. The absolute methyl radical column density and the line-of-sight average of the gas temperature were measured as functions of position in the discharge with input methane concentration 0 - 1%. The average absolute methyl radical density was nearly independent of position in the discharge and varied in the range as the input mole fraction varied in the range 0 - 1%. The gas temperature was measured using emission spectroscopy and was found to be independent of position throughout the discharge. An upper bound of was placed on the CH density, which gives an upper bound of 0.008 on the hydrogen dissociation ratio .

This publication has 19 references indexed in Scilit: