Abstract
We report on the design, fabrication, and verification of a proof-of-concept miniature fluorometer, which is designed to measure chlorophyll and colored dissolved organic matter (CDOM) concentration in aquatic environment. The system utilizes light emitting diodes (LEDs) for fluorescence excitation and absorption filters for excitation light attenuation. The excitation LED for chlorophyll has peak emission at 465 nm, and the excitation LED for CDOM has peak emission at 341 nm. Our device demonstrates the concept of attaching two different absorption filters on a single sensor array for measuring the fluorescence signal from two different fluorescent dyes. We have tested the system's ability to detect fluorescence from various concentrations of fluorescein as a close simulant and the calibration standard for chlorophyll, and quinine sulfate dihydrate (QSD) as a simulant and calibration standard for CDOM. We have successfully acquired the fluorescent signal for fluorescein between 0.7 and 1000 nM and for QSD between 2.6 and 638 nM.Keywords
Funding Information
- NSERC
- iCORE/AITF
This publication has 41 references indexed in Scilit:
- Estimation of Chlorophyll-a Concentration in Turbid Lake Using Spectral Smoothing and Derivative AnalysisInternational Journal of Environmental Research and Public Health, 2013
- Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopyNature Methods, 2012
- Valve controlled fluorescence detection system for remote sensing applicationsMicrofluidics and Nanofluidics, 2011
- Low Light CMOS Contact Imager with an Integrated Poly-Acrylic Emission Filter for Fluorescence DetectionSensors, 2010
- Temporal and spatial distribution of chlorophyll-a in surface waters of the Scotia Sea as determined by both shipboard measurements and satellite dataDeep Sea Research Part II: Topical Studies in Oceanography, 2004
- Modeling and simulation of luminescence detection platformsBiosensors and Bioelectronics, 2004
- Distribution and optical properties of CDOM in the Arabian Sea during the 1995 Southwest MonsoonDeep Sea Research Part II: Topical Studies in Oceanography, 1998
- Characterization of marine and terrestrial DOM in seawater using excitation-emission matrix spectroscopyMarine Chemistry, 1996
- Fluorescence characteristics of cyanobacteria (blue-green algae)Journal of Plankton Research, 1989
- A method for the determination of phytoplankton chlorophyll and phaeophytin by fluorescenceDeep Sea Research and Oceanographic Abstracts, 1963