Radiation Exposure in Minimally Invasive Cervical Spine Surgery: A Systematic Review
Preprint
- 23 April 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background and Objectives: Minimally invasive cervical spine surgery (MIS-CSS) re-lies heavily on intraoperative fluoroscopic imaging, raising concerns about radiation exposure to patients and surgical staff. Unlike lumbar MIS, cervical-specific radiation exposure has not been systematically reviewed, despite distinct anatomical considera-tions including proximity to the thyroid gland and lens of the eye. This review aims to quantify intraoperative radiation exposure during MIS cervical spine procedures and evaluate available dose-reduction strategies. Materials and Methods: A systematic literature search was conducted across Pub-Med/MEDLINE, Scopus, and Google Scholar in April 2026 following PRISMA 2020 guidelines. Studies reporting original quantitative radiation data during minimally invasive cervical spine procedures in adult patients (≥10 patients) were included. Quality was assessed using the MINORS tool and JBI checklist. Results: Seven studies encompassing 380 patients were included. Procedures com-prised ACDF (four studies), minimally invasive posterior cervical laminoforaminotomy (two studies), and CT-navigated cervical instrumentation (one study). Patient effective doses during ACDF ranged from 0.015 to 1.3 mSv, with thyroid doses of 0.194–0.290 mGy. Standalone ACDF reduced patient dose by 36–58% compared to plated ACDF (p < 0.001). Navigation-assisted posterior cervical foraminotomy achieved a median fluoroscopy time of 10 seconds with negligible staff exposure. Surgeon per-procedure exposure during cervical discectomy (chest 0.122 µSv, lens 3.1 µSv, hands 7.1 µSv) was approximately half that of lumbar discectomy. Conclusions: Radiation doses during individual MIS cervical procedures are generally within occupational safety limits; however, cumulative exposure warrants attention in high-volume surgeons. Standalone implant designs and intraoperative navigation represent effective, complementary dose-reduction strategies. Standardized prospec-tive research is needed to establish cervical-specific radiation safety benchmarks.Keywords
All Related Versions
- Version 1, 2026-04-23, Preprints
- Published version: Medicina, 62 (5), 977.
This publication has 16 references indexed in Scilit:
- Assessment of organ doses, peak skin doses and effective doses in patients undergoing anterior cervical discectomy and fusion utilising VirtualDose-IR softwareRadiation Protection Dosimetry, 2023
- Robotics Reduces Radiation Exposure in Minimally Invasive Lumbar Fusion Compared With NavigationSpine, 2022
- Minimising radiation exposure to the surgeon in minimally invasive spine surgeries: A systematic review of 15 studiesOrthopaedics & Traumatology: Surgery & Research, 2021
- Navigation and Robotics in Spinal Surgery: Where Are We Now?Neurosurgery, 2017
- Patient Dose in Fluoroscopically Guided Cervical Discectomy and FusionRadiation Protection Dosimetry, 2016
- Radiation Safety and Spine Surgery: Systematic Review of Exposure Limits and Methods to Minimize Radiation ExposureWorld Neurosurgery, 2014
- Does Less Invasive Spine Surgery Result in Increased Radiation Exposure? A Systematic ReviewClinical Orthopaedics and Related Research, 2014
- Minimizing Radiation Exposure in Minimally Invasive Spine SurgeryNeurosurgery Clinics of North America, 2014
- Increased cancer risk among surgeons in an orthopaedic hospitalOccupational Medicine, 2005
- Methodological index for non‐randomized studies (MINORS): development and validation of a new instrumentAnz Journal of Surgery, 2003