Analysis of pesticides based on immobilized housefly head acetylcholinesterase reactor with choline oxidase and horseradish peroxidase carbon paste electrode
Authors:
- 1 December 2020
- journal article
- research article
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 68 (2) , 306-314
Abstract
An automatic flow injection system (FIA) using the acetylcholinesterase (AChE) reactor connected with the choline oxidase (ChOx) and horseradish peroxidase (HRP) carbon paste electrode for organophosphorous (ORPs) and carbamate pesticides determination is exploited. The ORPs are measured based on the inhibition of AChE. Two different sources of AChE from eel and housefly head are studied, respectively. The detection limit for paraoxon (10 ppb) and carbofuran (23 ppb) is found in the housefly head AChE. The AChE from housefly head shows 16 times higher sensitivity than the enzyme from eel for paraoxon. The linear range of the housefly head AChE biosensor is 8–100 ppb. The throughput of five‐sample hour−1 is obtained with a good reproducibility. The fruit juice and river water samples are studied and show the feasibility for further applications.Keywords
This publication has 34 references indexed in Scilit:
- Acetylcholinesterase based biosensor for monitoring of Malathion and Acephate in food samples: A voltammetric studyFood Chemistry, 2014
- Biosensor based on acetylcholinesterase immobilized onto layered double hydroxides for flow injection/amperometric detection of organophosphate pesticidesBiosensors and Bioelectronics, 2013
- Molecular and Kinetic Properties of Two Acetylcholinesterases from the Western Honey Bee, Apis melliferaPLOS ONE, 2012
- Cholinesterase based amperometric biosensors for assay of anticholinergic compoundsInterdisciplinary Toxicology, 2009
- Insecticide identification using a flow injection analysis system with biosensors based on various cholinesterasesAnalytica Chimica Acta, 2005
- A Disposable Biosensor for Organophosphorus Nerve Agents Based on Carbon Nanotubes Modified Thick Film Strip ElectrodeElectroanalysis, 2005
- Amperometric flow-through biosensor for the determination of cholinesterase inhibitorsAnalytica Chimica Acta, 1999
- Characterisation of inhibitors of acetylcholinesterase by an automated amperometric flow-injection systemAnalytica Chimica Acta, 1995
- Reactivation of an immobilized enzyme reactor for the determination of acetylcholinesterase inhibitors Flow injection determination of paraoxonAnalytica Chimica Acta, 1994
- Flow-injection study of inhibition and reactivation of immobilized acetylcholinesterase: determination of the pesticides paraoxon and carbamoylcholineAnalytica Chimica Acta, 1993