Surface hardness and abrasive wear resistance of nitrogen-implanted steels

Authors:

Abstract
The hardness of nitrogen-implanted steel surfaces has been determined indirectly by a surface-sensitive abrasive wear technique using micrometer-size diamond particles. Wear rates were measured, as a function of depth, for implanted and unimplanted steel discs, and surface hardness was obtained from a verified relationship between wear rate and hardness. Tempered carbon steel implanted with nitrogen ions was significantly hardened to a depth commensurate with the implantation depth. Nitrogen-implanted 304 steel surfaces were softer than unimplanted ones, possibly due to interference with the work hardening which normally occurs during wearing. This softening effect persisted to depths several times the depth of implantaton. Composition-vs-depth profiles of implanted 304 steel obtained with Auger electron spectroscopy, indicated nitrogen migrated inward during wear.