Effect of Transition to Digital Mammography on Clinical Outcomes
Authors:
- Catherine G. GlynnCGCatherine G. Glynn
- Dione M. FarriaDFDione M. Farria
- Barbara S. MonseesBMBarbara S. Monsees
- Jennifer T. SalcmanJSJennifer T. Salcman
- Kimberly N. WieleKWKimberly N. Wiele
- Charles F. HildeboltCHCharles F. Hildebolt
- 1 September 2011
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 260 (3) , 664-670
Abstract
To determine the effect of transition to digital screening mammography on clinical outcome measures, including recall rate, cancer detection rate, and positive predictive value (PPV). Institutional review board approval and the need for informed consent were waived for this HIPAA-complaint study. Practice audit data were obtained for three breast imaging radiologists from 2004 to 2009. These data were sorted by time period into the following groups: baseline (2004-2005), digital year 1 (2007), digital year 2 (2008), and digital year 3 (2009). The χ(2) and Fisher exact tests were used to assess differences in proportions among and between years. Clinical outcomes based on lesion type from 2004 to 2008 were also compared. Computer-aided detection was used. The three radiologists interpreted 32 600 screen-film mammograms and 33 879 digital mammograms. Recall rates increased from 6.0% at baseline to 7.1% in digital year 1 (P < .0001) and continued to increase in subsequent years to 8.5%. The cancer detection rate increased from 3.3 at baseline to 5.3 in digital year 1 (P = .0061), and it remained higher than that at baseline in subsequent years. PPV after screening mammogaphy (PPV(1)) increased from 5.6% at baseline to 7.5% in digital year 1 and returned to baseline levels in digital year 3. In contrast, PPV after biopsy (PPV(3)) decreased from 44.5% at baseline to 30.3% in digital year 3 (P = .0021). From 2004 to 2008, 3444 patients with 3493 lesions were recalled. The percentage of recalls for calcifications increased from 13.8% at baseline to a peak of 23.9% in digital year 1 and 17.9% in digital year 2. Both PPV(1) and PPV(3) decreased for calcifications after the digital transition. Recall rate and cancer detection rate increase for at least 2 years after the transition to digital screening mammography. PPV(3) is significantly reduced after digital transition, primarily in patients with microcalcifications.Keywords
This publication has 16 references indexed in Scilit:
- Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral ratesEuropean Radiology, 2010
- Digital Mammography Leads to More Short-Term Follow-UpAmerican Journal of Roentgenology, 2010
- Breast Cancer Screening Results 5 Years after Introduction of Digital Mammography in a Population-based Screening ProgramRadiology, 2009
- Comparison of Digital Mammography and Screen-Film Mammography in Breast Cancer Screening: A Review in the Irish Breast Screening ProgramAmerican Journal of Roentgenology, 2009
- Digital Mammography: Its Impact on Recall Rates and Cancer Detection Rates in a Small Community-Based Radiology PracticeAmerican Journal of Roentgenology, 2009
- Full-Field Digital versus Screen-Film Mammography: Comparison within the UK Breast Screening Program and Systematic Review of Published DataRadiology, 2009
- Studies comparing screen-film mammography and full-field digital mammography in breast cancer screening: Updated reviewActa Radiologica, 2009
- Full-Field Digital Versus Screen-Film Mammography: Comparative Accuracy in Concurrent Screening CohortsAmerican Journal of Roentgenology, 2007
- Full-field digital mammography compared to screen film mammography in the prevalent round of a population-based screening programme: the Vestfold County StudyEuropean Radiology, 2007
- Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer ScreeningNew England Journal of Medicine, 2005