Relative SNR Measurements in Supine vs. Prone Breast MRI
Open Access
- 25 December 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2718-2725
Abstract
Purpose: Supine breast MRI has the potential to improve patient comfort compared to prone breast MRI, in addition to providing images in the same position as subsequent treatment protocols. Novel flexible coil arrays have enabled high SNR and parallel imaging in supine breast imaging, but the combined effect of coil and patient positioning on SNR has yet to be investigated. The aim of this study is to use a tissue‐independent metric to account for tissue deformation to compare SNR between prone and supine positions, using appropriate coils for each. Methods: Relative SNR (rSNR) metric is proposed as the ratio of SNR between a breast coil and a body coil. This metric is demonstrated to be tissue‐independent, allowing for easier SNR comparisons in cases of tissue deformation. We scanned 10 female subjects and compared the rSNR in segmented regions consisting of breast tissue, chest wall, and axilla between prone and supine breast imaging. Results: The rSNR was significantly higher in the breast tissue and chest wall in the supine position for all cases. The axilla rSNR was significantly higher in supine for four cases, with another four significantly higher in prone, and two showing no statistical difference. Using a distance‐from‐coil analysis, we found that the tissue is closer to the coil in supine, and that the supine coil provided higher SNR at distances closer than 4cm. Conclusion: Our results show that using a surface array coil in the supine position can provide higher SNR than a standard setup in most subjects for most relevant regions of breast MRI.Keywords
Funding Information
- GE Healthcare
- National Institutes of Health (R01‐CA249893)
- National Institutes of Health (R01‐EB009055)
This publication has 26 references indexed in Scilit:
- Multishot Diffusion‐Weighted MRI of the Breasts in the Supine vs. Prone PositionJournal of Magnetic Resonance Imaging, 2022
- Evaluation of a novel 8-channel RX coil for speech production MRI at 0.55 TMagnetic Resonance Materials in Physics, Biology and Medicine, 2022
- Global guidelines for breast cancer screening: A systematic reviewThe Breast, 2022
- Diffusion‐weighted double‐echo steady‐state with a three‐dimensional cones trajectory for non‐contrast‐enhanced breast MRIJournal of Magnetic Resonance Imaging, 2020
- Comparison of Abbreviated Breast MRI vs Digital Breast Tomosynthesis for Breast Cancer Detection Among Women With Dense Breasts Undergoing ScreeningJAMA, 2020
- Diffusion-weighted imaging of the breast—a consensus and mission statement from the EUSOBI International Breast Diffusion-Weighted Imaging working groupEuropean Radiology, 2019
- Supine breast MRIJournal of Magnetic Resonance Imaging, 2011
- Custom‐fitted 16‐channel bilateral breast coil for bidirectional parallel imagingMagnetic Resonance in Medicine, 2011
- Comprehensive quantification of signal‐to‐noise ratio and g‐factor for image‐based and k‐space‐based parallel imaging reconstructionsMagnetic Resonance in Medicine, 2008
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999