Outcome of heart transplantation after bridge-to-transplant strategy using various mechanical circulatory support devices
Authors:
Open Access
- 4 July 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 25 (6) , 918-924
Abstract
Orthotopic heart transplantation (OHT) is limited by a chronic shortage of donors. With the evolution of technology, more patients have been bridged to transplant (BTT) through various pathways using various types of mechanical circulatory support. We compared short- and long-term outcomes among these various strategies of BTT. We retrospectively reviewed 410 patients who had OHT between January 2009 and April 2015. Patients were divided into 4 groups according to BTT status: primary OHT without bridging (Group A, n = 246); bridge with implantable continuous-flow left ventricular assist device (CF-LVAD) (Group B, n = 130); bridge with short-term mechanical circulatory support (Group C, n = 16) and bridge with multiple mechanical circulatory supports, including short-term mechanical circulatory support and CF-LVAD (Group D, n = 18). Early and late outcomes after OHT were compared among the groups. The total duration of device support was 110.4 patient-years, 1.8 patient-years and 21.0 patient-years in Groups B, C and D, respectively. Patients who were bridged with CF-LVAD (Groups B and D) were more likely to have larger body size, blood type O, idiopathic dilated cardiomyopathy and ischaemic cardiomyopathy as an aetiology, lower total bilirubin level and longer waiting time on the United Network for Organ Sharing Status 1A. There was no statistical difference between the 4 groups in serum panel reactive antigen levels before OHT. Hospital mortality was 4% in Group A, 8% in Group B, 13% in Group C and 6% in Group D (P = 0.307). Post-transplant survival at 3 years was 80% in Group A, 82% in Group B, 75% in Group C and 88% in Group D (P = 0.752). BTT strategies using various mechanical circulatory support devices can provide comparable clinical outcomes to primary OHT. Flexibility in the use of both short-term mechanical circulatory support and CF-LVAD is necessary depending on the patient's background.Keywords
This publication has 20 references indexed in Scilit:
- Red Blood Cell Transfusions and the Risk of Allosensitization in Patients Awaiting Primary Kidney TransplantationTransplantation, 2014
- Prevalence and Prognostic Importance of Changes in Renal Function After Mechanical Circulatory SupportCirculation: Heart Failure, 2014
- Impact of Ventricular Assist Device Complications on Posttransplant Survival: An Analysis of the United Network of Organ Sharing DatabaseThe Annals of Thoracic Surgery, 2013
- Impact of long term left ventricular assist device therapy on donor allocation in cardiac transplantationThe Journal of Heart and Lung Transplantation, 2013
- Patients with low compared with high body mass index gain more weight after implantation of a continuous-flow left ventricular assist deviceThe Journal of Heart and Lung Transplantation, 2013
- Changes in Renal Function After Implantation of Continuous-Flow Left Ventricular Assist DevicesJACC, 2012
- Implantation technique of the CentriMag biventricular assist device allowing ambulatory rehabilitationInteractive CardioVascular and Thoracic Surgery, 2011
- Bridge to transplant experience: Factors influencing survival to and after cardiac transplantThe Journal of Thoracic and Cardiovascular Surgery, 2010
- United Network for Organ Sharing's expanded criteria donors: is stratification useful?*Clinical Transplantation, 2005
- Immunologic sensitization in recipients of left ventricular assist devicesThe Journal of Thoracic and Cardiovascular Surgery, 2003