Evaluation of giant-cell deposits on foldable intraocular lenses after combined cataract and glaucoma surgery
Authors:
- Ralph Y. ChuRCRalph Y. Chu
- Robert A. KreigerRKRobert A. Kreiger
- 1 June 2000
- journal article
- conference paper
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 26 (6) , 817-823
Abstract
To compare the incidence of inflammatory giant-cell deposits (IGCDs) on various foldable intraocular lenses (IOLs) after combined cataract and glaucoma surgery. The Phillips Eye Institute, Minneapolis, Minnesota, USA. In this prospective randomized clinical trial, 128 patients were randomized to receive a single-piece, first-generation silicone lens (n = 36); a 3-piece acrylic lens (n = 40); or 3-piece, second-generation silicone lens (n = 52). All patients had combined phacoemulsification and trabeculectomy with mitomycin-C by 1 surgeon using a standardized technique. Dilated biomicroscopy was used to identify and quantitate IGCDs on the surface of the IOLs using a 6-point grading scale. Inflammatory giant-cell deposits were identified on 21 of 128 IOLs. Lens design was the most significant risk factor for deposit formation (P =.004). Inflammatory giant-cell deposits were most common in the first-generation silicone plate lens group (33%), less common in the acrylic lens group (15%), and least common in the 3-piece, second-generation silicone group (5.8%). Density of the deposits was significantly greater on the plate lens than the acrylic or the 3-piece silicone lenses (P <.0001). Although IOL design was the most significant risk factor for IGCD formation, other significant risk factors included intraoperative pupil stretch (P =.02) and preoperative miotic use (P =.04). Inflammatory giant-cell deposit formation was significantly greater on first-generation silicone plate IOLs than on acrylic or second-generation silicone IOLs. The deposits were somewhat more common on acrylic IOLs than on second-generation silicone IOLs. However, this difference was not clinically or statistically significant.Keywords
This publication has 10 references indexed in Scilit:
- Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: Randomized comparison of the cellular reaction on the anterior lens surfaceJournal of Cataract & Refractive Surgery, 1998
- Comparative Study of Silicone versus Acrylic Foldable Lens Implantation in Primary Glaucoma Triple ProcedureOphthalmology, 1997
- Postoperative Cellular Reaction on Various Intraocular Lens MaterialsOphthalmology, 1997
- Surgical management of coincident cataract and glaucomaCurrent Opinion in Ophthalmology, 1997
- Clinical Assessment of Long-term Safety and Efficacy of a Widely Implanted Silicone Intraocular Lens MaterialAmerican Journal of Ophthalmology, 1997
- Laser Synechialysis to Prevent Membrane Recurrence on Silicone Intraocular LensesAmerican Journal of Ophthalmology, 1996
- Management of coincident glaucoma and cataractCurrent Opinion in Ophthalmology, 1996
- Two year clinical study of a soft acrylic intraocular lensJournal of Cataract & Refractive Surgery, 1996
- Reduced Vision Secondary to Pigmented Cellular Membranes on Silicone Intraocular LensesAmerican Journal of Ophthalmology, 1995
- Natural history of cellular deposits on the anterior intraocular lens surfaceJournal of Cataract & Refractive Surgery, 1995