Human Embryonic Growth and Development of the Cerebellum Using 3-Dimensional Ultrasound and Virtual Reality
Authors:
- M. RousianMRM. Rousian
- I. A. L. GroenenbergIGI. A. L. Groenenberg
- W. C. HopWHW. C. Hop
- A. H. J. KoningAKA. H. J. Koning
- P. J. van der SpekPSP. J. van der Spek
- N. ExaltoNEN. Exalto
- E. A. P. SteegersESE. A. P. Steegers
- 1 August 2013
- journal article
- research article
- Published by Springer Nature in Reproductive Sciences
- Vol. 20 (8) , 899-908
Abstract
The aim of our study was to evaluate the first trimester cerebellar growth and development using 2 different measuring techniques: 3-dimensional (3D) and virtual reality (VR) ultrasound visualization. The cerebellum measurements were related to gestational age (GA) and crown-rump length (CRL). Finally, the reproducibility of both the methods was tested. In a prospective cohort study, we collected 630 first trimester, serially obtained, 3D ultrasound scans of 112 uncomplicated pregnancies between 7 + 0 and 12 + 6 weeks of GA. Only scans with high-quality images of the fossa posterior were selected for the analysis. Measurements were performed offline in the coronal plane using 3D (4D view) and VR (V-Scope) software. The VR enables the observer to use all available dimensions in a data set by visualizing the volume as a "hologram." Total cerebellar diameter, left, and right hemispheric diameter, and thickness were measured using both the techniques. All measurements were performed 3 times and means were used in repeated measurements analysis. After exclusion criteria were applied 177 (28%) 3D data sets were available for further analysis. The median GA was 10 + 0 weeks and the median CRL was 31.4 mm (range: 5.2-79.0 mm). The cerebellar parameters could be measured from 7 gestational weeks onward. The total cerebellar diameter increased from 2.2 mm at 7 weeks of GA to 13.9 mm at 12 weeks of GA using VR and from 2.2 to 13.8 mm using 3D ultrasound. The reproducibility, established in a subset of 35 data sets, resulted in intraclass correlation coefficient values ≥0.98. It can be concluded that cerebellar measurements performed by the 2 methods proved to be reproducible and comparable with each other. However, VR-using all three dimensions-provides a superior method for the visualization of the cerebellum. The constructed reference values can be used to study normal and abnormal cerebellar growth and development.Keywords
This publication has 37 references indexed in Scilit:
- Agreement and reliability of pelvic floor measurements during contraction using three‐dimensional pelvic floor ultrasound and virtual realityUltrasound in Obstetrics & Gynecology, 2012
- The Fetal CerebellumJournal of Child Neurology, 2011
- Assessment of intracranial translucency (IT) in the detection of spina bifida at the 11–13‐week scanUltrasound in Obstetrics & Gynecology, 2009
- Reliability of three‐dimensional sonographic measurements in early pregnancy using virtual realityUltrasound in Obstetrics & Gynecology, 2008
- What information on fetal anatomy can be provided by a single first‐trimester transabdominal three‐dimensional sweep?Ultrasound in Obstetrics & Gynecology, 2008
- Detailed screening for fetal anomalies and cardiac defects at the 11–13‐week scanUltrasound in Obstetrics & Gynecology, 2006
- Qualified and trained sonographers in the US can perform early fetal anatomy scans between 11 and 14 weeksAmerican Journal of Obstetrics and Gynecology, 2004
- Sonographic markers of exencephaly at 9 + 3 weeks of gestationUltrasound in Obstetrics & Gynecology, 2000
- Sonoembryology: An organ‐oriented approach using a high‐frequency vaginal probeJournal of Clinical Ultrasound, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986