Managing transitions from oral factor Xa inhibitors to unfractionated heparin infusions
Authors:
- 15 December 2016
- journal article
- review article
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 73 (24) , 2037-2041
Abstract
Purpose Published evidence regarding the effects of oral factor Xa inhibitors on anticoagulation monitoring tests is reviewed with a focus on monitoring concerns that can arise during transitions to i.v. heparin therapy. Summary Assays that measure inhibition of factor Xa activity (i.e., anti-Xa assays) are widely used in U.S. institutions to monitor i.v. heparin therapy and, in some cases, for monitoring other types of anticoagulation therapy. Clinicians have raised concerns that the use of anti-Xa assays to monitor heparin levels in hospitalized patients who must be transitioned from oral factor Xa inhibitor therapy to i.v. unfractionated heparin (UFH) infusions could yield unquantifiable or inaccurate results, leading to unnecessary UFH dose reductions and potential treatment failures; the manufacturer labeling of oral factor Xa inhibitors (apixaban, edoxaban, and rivaroxaban) does not provide specific guidance on this issue. Results of a literature review indicated that residual effects of oral factor Xa inhibitor use can result in substantial interference with the currently available chromogenic anti-Xa assays but negligible to moderate effects on global coagulation assays, which measure activated partial thromboplastin time (aPTT) or prothrombin time. Therefore, during the transition from an oral factor Xa inhibitor to i.v. UFH therapy, it may be prudent to consider an aPTT assay for anticoagulation monitoring. Conclusion The use of oral factor Xa inhibitors appears to affect the accuracy of anti-Xa assay results, with results of global coagulation assays affected to a lesser degree.Keywords
This publication has 17 references indexed in Scilit:
- Laboratory Measurement of the Anticoagulant Activity of the Non–Vitamin K Oral AnticoagulantsJACC, 2014
- Assessment of apixaban plasma levels by laboratory tests: suitability of three anti-Xa assaysThrombosis and Haemostasis, 2014
- Comparison of calibrated chromogenic anti-Xa assay and PT tests with LC-MS/MS for the therapeutic monitoring of patients treated with rivaroxabanThrombosis and Haemostasis, 2013
- Parenteral AnticoagulantsChest, 2012
- Determination of the anticoagulant effects of new oral anticoagulants: an unmet needExpert Review of Hematology, 2012
- Accurate determination of rivaroxaban levels requires different calibrator sets but not addition of antithrombinThrombosis and Haemostasis, 2012
- Chromogenic laboratory assays to measure the factor Xa-inhibiting properties of apixaban—an oral, direct and selective factor Xa inhibitorJournal of Thrombosis and Thrombolysis, 2011
- Laboratory Monitoring of Heparin Therapy: Partial Thromboplastin Time or Anti-Xa Assay?Laboratory Medicine, 2009
- Antithrombotic effects of factor Xa inhibition with DU-176b: Phase-I study of an oral, direct factor Xa inhibitor using an ex-vivo flow chamberThrombosis and Haemostasis, 2007
- Coagulation AssaysCirculation, 2005