A further analysis of why pulmonary venous pressure rises after the onset of LV dysfunction
Authors:
- S. MagderSMS. Magder
- S. VeerassamySVS. Veerassamy
- J. H. T. BatesJBJ. H. T. Bates
Open Access
- 1 January 2009
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 106 (1) , 81-90
Abstract
Based on a dynamic computational model of the circulation, Burkhoff and Tyberg ( Am J Physiol Heart Circ Physiol 265: H1819–H1828, 1993) concluded that the rise in pulmonary venous pressure (Pvp) with left ventricular (LV) dysfunction requires a decrease in vascular capacitance and transfer of unstressed volume to stressed volume (ν). We argue that the values they used for venous resistance (Rvs), venous compliance (Cvs), and ν were too low, and changing these values significantly changes the conclusion. We used a computational model of the circulation that was similar to theirs, but we made Rvs four times higher (0.06 versus 0.015 mmHg·s·ml−1), Cvs larger (110 versus 70 ml/mmHg), and ν larger (1,400 versus 750 ml); all other parameters, including those for the heart, were essentially the same. We simulated left ventricular dysfunction by decreasing end-systolic elastance (Eeslv) as they did and examined changes in cardiac output, arterial blood pressure, and Pvp. We then examined the effect of changes in Rvs, heart rate, and ν when Eeslv was depressed with and without pericardial constraint. In contrast to their findings, with our parameters the model predicts that decreasing Eeslv substantially increases Pvp. Furthermore, increasing systemic vascular resistance or decreasing Rvs or heart rate produces large increases in Pvp when Eeslv is reduced. Pericardial constraint limits the changes in Pvp. In conclusion, when Rvs and Cvs are increased, baseline ν must be higher to maintain normal cardiac output. This increased volume can shift between compartments under flow conditions and account for the increase in Pvp with decreased left ventricular function even without recruitment of unstressed volume.Keywords
This publication has 34 references indexed in Scilit:
- The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correctJournal of Applied Physiology, 2006
- COUNTERPOINT: THE CLASSICAL GUYTON VIEW THAT MEAN SYSTEMIC PRESSURE, RIGHT ATRIAL PRESSURE, AND VENOUS RESISTANCE GOVERN VENOUS RETURN IS NOT CORRECTJournal of Applied Physiology, 2006
- Endotoxin and the mechanical properties of the canine peripheral circulationJournal of Critical Care, 1991
- Cardiac and peripheral circulatory responses to angiotension and vasopressin in dogs.Journal of Clinical Investigation, 1988
- Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium.Circulation Research, 1985
- Assessment of pericardial constraint in dogs.Circulation, 1985
- Effects of hypoxia on the closing pressure of the canine systemic arterial circulation.Circulation Research, 1981
- The cardiac and vascular factors that determine systemic blood flow.Circulation Research, 1979
- The ventricular pressure-volume diagram revisited.Circulation Research, 1978
- Effect of thoracic blood volume changes on steady state cardiac output.Circulation Research, 1976