Cadaveric Study of Glenohumeral Translation Using Electromagnetic Sensors
Authors:
- James E. TiboneJTJames E. Tibone
- Patrick J. McMahonPMPatrick J. McMahon
- Thay Q. LeeTLThay Q. Lee
- 1 July 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 400 (400) , 88-92
Abstract
Clinical methods for measuring shoulder translation rely heavily on the experience of the examiner and remain largely subjective, prone to errors of interobserver and intraobserver reproducibility. Accurate in vitro methods of measuring glenohumeral translation exist. The purpose of the current study was to evaluate the accuracy of computerized electromagnetic spatial sensors applied to the skin, in measuring glenohumeral translation under simulated conditions of a standard shoulder examination. Seven thawed, fresh-frozen shoulder specimens from cadavers were used in the study. Soft tissue and skin were not removed. The specimens were mounted to simulate clinical positions of patients having an anteroposterior drawer or load-and-shift test. A series of anterior and posterior displacements were done manually under two conditions. Condition I: Electromagnetic position sensors were taped to skin and held beneath the examiner’s fingers; and Condition II: Sensors were fixed rigidly to pins inserted into the glenoid and humeral head, respectively. Displacement values between conditions, within trials, and among specimens were compared for accuracy and reproducibility. Strong agreement was shown between Condition I and Condition II for the anterior and posterior directions (interclass correlation coefficients 0.81 and 0.86, respectively). Simple linear regression revealed a significant association between conditions in the anterior and posterior directions. Reproducibility between trials under each condition was extremely high, with interclass correlation coefficients greater than or equal to 0.98 regardless of direction of displacement or testing condition. The data from the current study show that cutaneous application of electromagnetic position sensors to the shoulder can accurately and reproducibly measure true glenohumeral translation under testing conditions that mimic a standard, clinical shoulder examination.Keywords
This publication has 11 references indexed in Scilit:
- Translation of the glenoihumeral joint with the patient under anesthesiaJournal of Shoulder and Elbow Surgery, 1996
- Accuracy of an electromagnetic tracking device: A study of the optimal operating range and metal interferenceJournal of Biomechanics, 1996
- Shoulder instability Assessment of anterior-posterior translation with a knee laxity testerActa Orthopaedica, 1995
- Laxity of the normal glenohumeral joint: A quantitative in vivo assessmentJournal of Shoulder and Elbow Surgery, 1992
- Genucom, KT-1000, and Stryker knee laxity measuring device comparisonsThe American Journal of Sports Medicine, 1989
- Cineradiographic studies with shoulder instabilitiesThe American Journal of Sports Medicine, 1988
- Instrumented measurement of anterior laxity of the knee.Journal of Bone and Joint Surgery, 1985
- Clinical assessment of instability of the shoulder. With special reference to anterior and posterior drawer testsThe Journal of Bone and Joint Surgery. British volume, 1984
- The stability of the shoulder joint in stress radiographyArchives of orthopaedic and trauma surgery, 1984
- Inferior capsular shift for involuntary inferior and multidirectional instability of the shoulder. A preliminary report.Journal of Bone and Joint Surgery, 1980