11—CALIBRATING NEAR-INFRA-RED REFLECTANCE INSTRUMENTS FOR WOOL BASE AND WOOL CONTENT

Authors:

Abstract
An investigation is reported in which three instruments that use filters for reflectance measurements in the near-infra-red region were calibrated for wool base and wool content. The use of wavelengths suitable for the analysis of cereals gave calibration root mean square deviations of 2.2–3.0% wool base and 2.6% wool content, compared with the results for the standard IWTO test of 1.0% and 1.7%, respectively. Alternative wavelengths that were available in one of the instruments reduced the root mean square deviations to 1.8% and 1.4%, respectively. The calibrations for wool base with these wavelengths had deviations that were too large to enable the test to be an alternative to the accepted IWTO test method.