Finite element model of the impaction of a press-fitted acetabular cup
- 4 August 2016
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (5) , 781-791
Abstract
Press-fit surgical procedures aim at providing primary stability to acetabular cup (AC) implants. Impact analysis constitutes a powerful approach to retrieve the AC implant insertion properties. The aim of this numerical study was to investigate the dynamic interaction occurring between the hammer, the ancillary and bone tissue during the impact and to assess the potential of impact analysis to retrieve AC implant insertion conditions. A dynamic two-dimensional axisymmetric model was developed to simulate the impaction of the AC implant into bone tissue assuming friction at the bone–implant interface and large deformations. Different values of interference fit (from 0.5 to 2 mm) and impact velocities (from 1 to 2 m.s−1) were considered. For each configuration, the variation of the force applied between the hammer and the ancillary was analyzed and an indicator I was determined based on the impact momentum of the signal. The simulated results are compared to the experiments. The value of the polar gap decreases with the impact velocity and increases with the interference fit. The bone–implant contact area was significantly correlated with the resonance frequency (R 2 = 0.94) and the indicator (R 2 = 0.95). The results show the potential of impact analyses to retrieve the bone–implant contact properties.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR-13-PRTS-0015, ANR-13-PRTS-0015)
This publication has 36 references indexed in Scilit:
- Experimental Validation of Finite Element Models of Intact and Implanted Composite Hemipelvises Using Digital Image CorrelationJournal of Biomechanical Engineering, 2012
- Assessment of implant stability of cementless hip prostheses through the frequency response function of the stem–bone systemSensors and Actuators A: Physical, 2010
- In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prosthesesJournal of Orthopaedic Surgery and Research, 2009
- The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hipThe Journal of Bone and Joint Surgery. British volume, 2007
- The number of screws, bone quality, and friction coefficient affect acetabular cup stabilityMedical Engineering & Physics, 2006
- The relation between micromotion and screw fixation in acetabular cupComputer Methods and Programs in Biomedicine, 2006
- Acetabular Component Deformation with Press-Fit FixationThe Journal of Arthroplasty, 2006
- Stability of press-fit acetabular cupsThe Journal of Arthroplasty, 1992
- Tissue response to porous-coated implants lacking initial bone appositionThe Journal of Arthroplasty, 1988
- Implant fixation improved by close fit Cylindrical implant – bone interface studied in rabbitsActa Orthopaedica, 1988