Bite Force Evaluation of Conventional Plating System Versus Locking Plating System for Mandibular Fracture
- 10 March 2015
- journal article
- Published by Springer Nature in Journal of Maxillofacial and Oral Surgery
- Vol. 14 (4) , 972-978
Abstract
To compare and evaluate the variation in recorded bite forces in patients with mandibular fractures undergoing open reduction and rigid internal fixation using standard 2.0 versus 2.0 mm locking miniplates. A prospective randomized study was conducted for the treatment of mandibular fractures. Twenty adult patients with 31 mandibular fractures requiring an open reduction and internal fixation were included in the study. The sample was divided into two groups depending upon whether the patients received 2.0 mm non-locking (standard) or 2.0 mm locking miniplates for rigid fixation respectively. Bite force was evaluated at 1st, 3rd and 6th week after the open reduction and rigid fixation using miniplates. A statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. The results showed that amongst locking vs non-locking miniplates, the former showed a greater bite force enhancement when compared to baseline values(post-trauma).A comparison between 2nd day post-operative vs 6th week post-operative values showed a significant increase in bite force in Group 1 (non-locking) (p < 0.05) whereas the values Were highly significant (p < 0.001) in Group 2 (locking Plate). The findings were suggestive that the efficacy of locking miniplates plate in mandibular fracture was superior in terms of bearing the masticatory loads during osteosynthesis of the fracture. However, the clinical results were almost similar to those seen with non-locking miniplate osteosynthesis.Keywords
This publication has 24 references indexed in Scilit:
- A Comparative Biomechanical Evaluation of Mandibular Condyle Fracture Plating TechniquesJournal of Oral and Maxillofacial Surgery, 2006
- Transoral 2.0-mm Locking Miniplate Fixation of Mandibular Fractures Plus 1 Week of Maxillomandibular Fixation: A Prospective StudyJournal of Oral and Maxillofacial Surgery, 2005
- An in vitro evaluation of miniplate fixation techniques for fractures of the atrophic edentulous mandibleInternational Journal of Oral and Maxillofacial Surgery, 2005
- The use of dermis grafts after discectomy for internal derangement of the temporomandibular jointJournal of Oral and Maxillofacial Surgery, 2005
- Bite forces in patients after treatment of mandibular angle fractures with miniplate osteosynthesis according to ChampyInternational Journal of Oral and Maxillofacial Surgery, 2002
- A comparative review of 266 mandibular fractures with internal fixation using rigid (AO/ASIF) plates or mini-platesBritish Journal of Oral and Maxillofacial Surgery, 1996
- Fracture line stability as a function of the internal fixation systemJournal of Oral and Maxillofacial Surgery, 1995
- Bite forces in patients treated for mandibular angle fractures: Implications for fixation recommendationsJournal of Oral and Maxillofacial Surgery, 1994
- Mandibular Reconstruction with the Titanium Hollow Screw Reconstruction Plate (THORP) SystemPlastic and Reconstructive Surgery, 1988
- Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: Biomechanical aspectsInternational Journal of Oral and Maxillofacial Surgery, 1988