Kinetic model-informed deep learning for multiplexed PET image separation
Authors:
Open Access
- 1 July 2024
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-24
Abstract
Background: Multiplexed positron emission tomography (mPET) imaging can measure physiological and pathological information from different tracers simultaneously in a single scan. Separation of the multiplexed PET signals within a single PET scan is challenging due to the fact that each tracer gives rise to indistinguishable 511 keV photon pairs, and thus no unique energy information for differentiating the source of each photon pair. Methods: Recently, many applications of deep learning for mPET image separation have been concentrated on pure data-driven methods, e.g., training a neural network to separate mPET images into single-tracer dynamic/static images. These methods use over-parameterized networks with only a very weak inductive prior. In this work, we improve the inductive prior of the deep network by incorporating a general kinetic model based on spectral analysis. The model is incorporated, along with deep networks, into an unrolled image-space version of an iterative fully 4D PET reconstruction algorithm. Results: The performance of the proposed method was evaluated on a simulated brain image dataset for dual-tracer [ $$^{18}$$ F]FDG+[ $$^{11}$$ C]MET PET image separation. The results demonstrate that the proposed method can achieve separation performance comparable to that obtained with single-tracer imaging. In addition, the proposed method outperformed the model-based separation methods (the conventional voxel-wise multi-tracer compartment modeling method (v-MTCM) and the image-space dual-tracer version of the fully 4D PET image reconstruction algorithm (IS-F4D)), as well as a pure data-driven separation [using a convolutional encoder-decoder (CED)], with fewer training examples. Conclusions: This work proposes a kinetic model-informed unrolled deep learning method for mPET image separation. In simulation studies, the method proved able to outperform both the conventional v-MTCM method and a pure data-driven CED with less training data.
Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/S032789/1)
- Wellcome EPSRC Centre for Medical Engineering (WT203148/Z/16/Z)
This publication has 56 references indexed in Scilit:
- Spatiotemporal Attention Constrained Deep Learning Framework for Dual-Tracer PET Imaging2022
- Temporal information‐guided dynamic dual‐tracer PET signal separation networkMedical Physics, 2022
- Positron emission tomography with additional γ -ray detectors for multiple-tracer imagingMedical Physics, 2017
- Dual-Tracer PET Using Generalized Factor Analysis of Dynamic SequencesMolecular Imaging and Biology, 2013
- Simultaneous Dual-tracer PET Imaging of the Rat Brain and its Application in the Study of Cerebral IschemiaMolecular Imaging and Biology, 2010
- Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2006
- Usefulness of 11C-methionine PET in the evaluation of brain lesions that are hypo- or isometabolic on 18F-FDG PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2001
- Double-injection FDG method to measure cerebral glucose metabolism twice in a single procedureAnnals of Nuclear Medicine, 2001
- Normal variants, artefacts and interpretative pitfalls in PET imaging with 18-fluoro-2-deoxyglucose and carbon-11 methionineEuropean Journal of Nuclear Medicine and Molecular Imaging, 1999
- Measurement of the blood‐brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental conceptsMagnetic Resonance in Medicine, 1991