Simultaneous Dual Frequency $^{1}{\rm H}$ and $^{19}{\rm F}$ Open Coil Imaging of Arthritic Rabbit Knee at 3T
- 9 August 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (1) , 22-27
Abstract
The combination of sensitive magnetic resonance techniques with a selective site-targeted nanoparticle contrast agent has a demonstrated utility for molecular imaging studies. By detecting a unique signature of the contrast agent, this approach can be employed to identify specific bio-molecular markers and observe cellular-level processes within a large and complex organism (e.g., in vivo rabbit). The objective of the present investigation was to design, fabricate and characterize a radio-frequency (RF) coil for the dual frequency ( 1 H and 19 F) simultaneous collection of both nuclei images in a 3T field, in order to facilitate studies of arthritic knee degradation in rabbits. The coil supports both transmit and receive modes. The supporting activities included: 1) establishing a technical database for calculating the required coil parameters, 2) selection of a favorable coil geometry, and 3) adaption of existing RF measurement techniques to the design, development and electrical evaluation of the coil. The coil is used in conjunction with a Philips Medical Systems clinical MRI scanner, requiring all RF simultaneous dual frequency ( 1 H and 19 F) coils to operate in both transmit and receive modes. A commercial version of SPICE (simulation program with integrated circuit emphasis) was used to estimate significant operational parameters prior to fabricating the imaging coil. Excellent images were obtained with the fabricated coil and no operational problems were observed that would limit the use of other coil geometries and field strengths.Keywords
This publication has 9 references indexed in Scilit:
- Noise figure limits for circular loop MR coilsMagnetic Resonance in Medicine, 2009
- Radio frequency coil technology for small‐animal MRINMR in Biomedicine, 2007
- NMR Probeheads for Biophysical and Biomedical Experiments2006
- Quantitative “magnetic resonance immunohistochemistry” with ligand‐targeted 19F nanoparticlesMagnetic Resonance in Medicine, 2004
- Surface and Gradiometer Coils near a Conducting Body: The Lift-off EffectJournal of Magnetic Resonance, 1998
- A simple method to incorporate the effects of an RF shield into RF resonator analysis for MRI applicationsIEEE Transactions on Biomedical Engineering, 1995
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- A 64 MHz half-birdcage resonator for clinical imagingJournal of Magnetic Resonance (1969), 1990
- DELIGHT.SPICE: an optimization-based system for the design of integrated circuitsIEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems, 1988