ASD and PFO closure with the Solysafe septal occluder—Results of a prospective multicenter pilot study
- 15 February 2008
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 71 (3) , 398-402
Abstract
Objective: We report the results of a prospective multicenter pilot study performed in Germany, Sweden, and Switzerland with a new self‐centering device for transcatheter closure of an atrial septal defect (ASD) or a patent foramen ovale (PFO) called the Solysafe Septal Occluder. Interventions: The device was successfully implanted in 44 patients. In 15 patients with a median age of 40 years (range 6–76 years), a Solysafe device was successfully implanted in an ASD. The median size of the stretched defects was 17 mm (range 10–21 mm). Three 15‐mm devices, eight 20‐mm devices, and four 25‐mm devices were used. Procedure time ranged from 40 to 107 min (median 66 min) and fluoroscopic time from 5.3 to 17.5 min (median 12 min). In 29 patients with a median age of 47 years (range 15–78 years), a Solysafe device was implanted in a PFO. The procedure time ranged from 21 to 155 min (median 51 min) and fluoroscopic time from 3.1 to 31.3 min (median 7.6 min). Results: At discharge, 1 of the 29 patients (3%) had a small shunt. No patient in either the ASD or the PFO group had any major complication. Six months after implantation, the overall closure rate with the Solysafe septal occluder in both groups was 100% (44/44). Conclusion: With the self‐centering Solysafe Septal Occluder, PFOs, and ASDs with a stretched diameter of up to 21 mm can be effectively closed with very high occlusion rates.Keywords
This publication has 15 references indexed in Scilit:
- Transcatheter patent foramen ovale closure using the premere PFO occlusion systemCatheterization and Cardiovascular Interventions, 2006
- Analysis of factors related to successful transcatheter closure of secundum atrial septal defects using the HELEX septal occluderAmerican Heart Journal, 2006
- Comparison of outcome and complications using different types of devices for percutaneous closure of a secundum atrial septal defect in adults: A single‐center experienceCatheterization and Cardiovascular Interventions, 2006
- Atrial and Ventricular Septal Defects Can Safely Be Closed by Percutaneous InterventionJournal of Interventional Cardiology, 2005
- Challenges Encountered During Closure of Atrial Septal DefectsPediatric Cardiology, 2005
- Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluderJACC, 2005
- CardioSEAL/STARflex versus Amplatzer devices for percutaneous closure of small to moderate (up to 18 mm) atrial septal defectsAmerican Heart Journal, 2004
- Transcatheter closure as standard treatment for most interatrial defects: experience in 200 patients treated with the Amplatzer ™ Septal OccluderCardiology in the Young, 1999
- Percutaneous closure of secundum atrial septal defect with a new self centring device (“angel wings”)Heart, 1998
- International experience with secundum atrial septal defect occlusion by the buttoned deviceAmerican Heart Journal, 1994