Operator variability in scan positioning is a major component of HR-pQCT precision error and is reduced by standardized training
- 30 July 2016
- journal article
- research article
- Published by Springer Nature in Osteoporosis International
- Vol. 28 (1) , 245-257
Abstract
Summary In this study, we determined that operator positioning precision contributes significant measurement error in high-resolution peripheral quantitative computed tomography (HR-pQCT). Moreover, we developed software to quantify intra- and inter-operator variability and demonstrated that standard positioning training (now available as a web-based application) can significantly reduce inter-operator variability. Introduction HR-pQCT is increasingly used to assess bone quality, fracture risk, and anti-fracture interventions. The contribution of the operator has not been adequately accounted in measurement precision. Operators acquire a 2D projection (“scout view image”) and define the region to be scanned by positioning a “reference line” on a standard anatomical landmark. In this study, we (i) evaluated the contribution of positioning variability to in vivo measurement precision, (ii) measured intra- and inter-operator positioning variability, and (iii) tested if custom training software led to superior reproducibility in new operators compared to experienced operators. Methods To evaluate the operator in vivo measurement precision, we compared precision errors calculated in 64 co-registered and non-co-registered scan-rescan images. To quantify operator variability, we developed software that simulates the positioning process of the scanner’s software. Eight experienced operators positioned reference lines on scout view images designed to test intra- and inter-operator reproducibility. Finally, we developed modules for training and evaluation of reference line positioning. We enrolled six new operators to participate in a common training, followed by the same reproducibility experiments performed by the experienced group. Results In vivo precision errors were up to threefold greater (Tt.BMD and Ct.Th) when variability in scan positioning was included. The inter-operator precision errors were significantly greater than the short-term intra-operator precision (p < 0.001). New trained operators achieved comparable intra-operator reproducibility to experienced operators and lower inter-operator reproducibility (p < 0.001). Precision errors were significantly greater for the radius than for the tibia. Conclusion Operator reference line positioning contributes significantly to in vivo measurement precision and is significantly greater for multi-operator datasets. Inter-operator variability can be significantly reduced using a systematic training platform, now available online (http://webapps.radiology.ucsf.edu/refline/).Keywords
Funding Information
- National Institutes of Health (R01 AR060700)
- National Institutes of Health (U01 AG027810, U01 AG042124, U01 AG042139, U01 AG042140, U01 AG042143, U01 AG042145, U01 AG042168, U01 AR066160, and UL1 TR000128)
This publication has 34 references indexed in Scilit:
- High-Resolution Peripheral Quantitative Computed Tomography for the Assessment of Bone Strength and Structure: A Review by the Canadian Bone Strength Working GroupCurrent Osteoporosis Reports, 2013
- Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomographyJournal of Bone and Mineral Research, 2012
- A longitudinal HR-pQCT study of alendronate treatment in postmenopausal women with low bone density: Relations among density, cortical and trabecular microarchitecture, biomechanics, and bone turnoverJournal of Bone and Mineral Research, 2010
- Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCTBone, 2010
- Strontium ranelate and alendronate have differing effects on distal tibia bone microstructure in women with osteoporosisRheumatology International, 2010
- Age- and gender-related differences in the geometric properties and biomechanical significance of intracortical porosity in the distal radius and tibiaJournal of Bone and Mineral Research, 2010
- Assessing forearm fracture risk in postmenopausal womenOsteoporosis International, 2009
- Bone Structure at the Distal Radius During Adolescent GrowthJournal of Bone and Mineral Research, 2009
- Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysisBone, 2007
- Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniquesOsteoporosis International, 1995