Quantifying Distal Deltoid Disruption With Linear versus Curvilinear Plating of Proximal Humerus Fractures: A Cadaveric Study
- 1 October 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 38 (10) , 566-570
Abstract
BACKGROUND: Plate fixation of proximal humeral fractures is usually associated with some degree of distal deltoid dissection. The purpose of this study was to quantify deltoid release with standard linear versus curvilinear plates used in the repair of proximal humeral fractures. METHODS: Seven nonpaired, fresh-frozen, clavicle-to-fingertip cadaveric shoulders met the inclusion criteria for this study. Four different proximal humerus implants were tested. One of these plates was curvilinear (89 mm), and the other 3 plates were linear (85, 98, 109 mm in length). Plates were compared based on the amount of deltoid insertion released for proper plate positioning. An analysis of variance with post hoc Tukey tests was conducted to compare mean deltoid disruption across the 3 shortest plate types from each manufacturer. A linear regression analysis was conducted to analyze the effect of plate length on mean deltoid release. RESULTS: The mean deltoid insertion length was 39.6 ± 8.6 mm (n = 7). The curvilinear plate (89 mm) required the least amount of average deltoid release at 4.1 ± 4.5 mm, or 12.1% of the deltoid insertion. Independent analysis of variance, including the 3 shortest plates from each manufacturer, found a significant effect of which plate was used on the amount of deltoid disruption that resulted (F(2, 18) = 18.0, P < 0.001, ω = 0.6). A linear regression including all 4 plates demonstrated a statistically significant direct relationship between the plate length and the mean deltoid released (y = 0.6x − 43.8, r2 = 4). CONCLUSION: This study demonstrates that proximal humerus plate length has a direct relationship with the amount of deltoid released during plating. Although deltoid disruption is length dependent, plate shape (curvilinear vs. linear) could also be contributory. When comparing a curvilinear and a linear plate of similar lengths, the curvilinear plate resulted in less mean deltoid release.Keywords
This publication has 17 references indexed in Scilit:
- Trending a decade of proximal humerus fracture management in older adultsJSES International, 2021
- Salvage reverse total shoulder arthroplasty for failed operative treatment of proximal humeral fractures in patients younger than 60 years: long-term resultsJournal of Shoulder and Elbow Surgery, 2020
- Nationwide trends in management of proximal humeral fractures: an analysis of 77,966 cases from 2008 to 2017Journal of Shoulder and Elbow Surgery, 2019
- Epidemiology of proximal humeral fractures: a detailed survey of 711 patients in a metropolitan areaJournal of Shoulder and Elbow Surgery, 2017
- Reverse total shoulder arthroplasty for failed open reduction and internal fixation of fractures of the proximal humerusJournal of Shoulder and Elbow Surgery, 2017
- Treatment of proximal humerus fractures with locking plates: A systematic reviewJournal of Shoulder and Elbow Surgery, 2009
- The anatomy of the deltoid insertionJournal of Shoulder and Elbow Surgery, 2009
- Helical plating of the proximal humerusInjury, 2005
- A cadaveric study on the anatomy of the deltoid insertion and its relationship to the deltopectoral approach to the proximal humerusJournal of Shoulder and Elbow Surgery, 2004
- Loss of the deltoid after shoulder operations: An operative disasterJournal of Shoulder and Elbow Surgery, 1994