Blood metal ion concentrations after hip resurfacing arthroplasty
- 1 October 2009
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 91-B (10) , 1287-1295
Abstract
There have been no large comparative studies of the blood levels of metal ions after implantation of commercially available hip resurfacing devices which have taken into account the effects of femoral size and inclination and anteversion of the acetabular component. We present the results in 90 patients with unilateral articular surface replacement (ASR) hip resurfacings (mean time to blood sampling 26 months) and 70 patients with unilateral Birmingham Hip Resurfacing (BHR) implants (mean time 47 months). The whole blood and serum chromium (Cr) and cobalt (Co) concentrations were inversely related to the size of the femoral component in both groups (p < 0.05). Cr and Co were more strongly influenced by the position of the acetabular component in the case of the ASR, with an increase in metal ions observed at inclinations > 45° and anteversion angles of < 10° and > 20°. These levels were only increased in the BHR group when the acetabular component was implanted with an inclination > 55°. A significant relationship was identified between the anteversion of the BHR acetabular component and the levels of Cr and Co (p < 0.05 for Co), with an increase observed at anteversion angles < 10° and > 20°. The median whole blood and serum Cr concentrations of the male ASR patients were significantly lower than those of the BHR men (p < 0.001). This indicates that reduced diametral clearance may equate to a reduction in metal ion concentrations in larger joints with satisfactory orientation of the acetabular component.Keywords
This publication has 30 references indexed in Scilit:
- Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip ResurfacingJournal of Bone and Joint Surgery, 2008
- The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hipThe Journal of Bone and Joint Surgery. British volume, 2008
- Revision of metal-on-metal resurfacing arthroplasty of the hipThe Journal of Bone and Joint Surgery. British volume, 2008
- Modes of Implant Failure After Hip Resurfacing: Morphological and Wear Analysis of 267 Retrieval SpecimensJournal of Bone and Joint Surgery, 2008
- Pseudotumours associated with metal-on-metal hip resurfacingsThe Journal of Bone and Joint Surgery. British volume, 2008
- The five-year results of the Birmingham Hip Resurfacing arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2008
- Influence of the Clearance on In-Vitro Tribology of Large Diameter Metal-on-Metal Articulations Pertaining to Resurfacing Hip ImplantsOrthopedic Clinics of North America, 2005
- Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritisThe Journal of Bone and Joint Surgery. British volume, 2004
- Metal-on-Metal Hybrid Surface Arthroplasty: Two to Six-Year Follow-up StudyJournal of Bone and Joint Surgery, 2004
- The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001