A Paired Phase and Magnitude Reconstruction for Advanced Diffusion-Weighted Imaging
- 20 June 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (12) , 3425-3435
Abstract
Objective : Multi-shot interleaved echo planer imaging (Ms-iEPI) can obtain diffusion-weighted images (DWI) with high spatial resolution and low distortion, but suffers from ghost artifacts introduced by phase variations between shots. In this work, we aim at solving the ms-iEPI DWI reconstructions under inter-shot motions and ultra-high b-values. Methods : An iteratively joint estimation model with paired phase and magnitude priors is proposed to regularize the reconstruction (PAIR). The former prior is low-rankness in the k-space domain. The latter explores similar edges among multi-b-value and multi-direction DWI with weighted total variation in the image domain. The weighted total variation transfers edge information from the high SNR images (b-value = 0) to DWI reconstructions, achieving simultaneously noise suppression and image edges preservation. Results : Results on simulated and in vivo data show that PAIR can remove inter-shot motion artifacts very well (8 shots) and suppress the noise under the ultra-high b-value (4000 s/mm 2 ) significantly. Conclusion : The joint estimation model PAIR with complementary priors has a good performance on challenging reconstructions under inter-shot motions and a low signal-to-noise ratio. Significance : PAIR has potential in advanced clinical DWI applications and microstructure research.Keywords
All Related Versions
Funding Information
- National Natural Science Foundation of China (62122064, 61971361, 61871341)
- Natural Science Foundation of Fujian Province of China (2021J011184)
- President Fund of Xiamen University (20720220063)
- Xiamen University Nanqiang Outstanding Talents Program
This publication has 39 references indexed in Scilit:
- Diagnostic accuracy of ultra-high-b-value 3.0-T diffusion-weighted MR imaging for detection of prostate cancerClinical Imaging, 2012
- High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 TMagnetic Resonance in Medicine, 2012
- The utility of high b-value DWI in evaluation of ischemic stroke at 3TEuropean Journal of Radiology, 2011
- Diffusion-Weighted Imaging, Diffusion-Tensor Imaging, and Fiber Tractography of the Spinal CordMagnetic Resonance Imaging Clinics of North America, 2009
- Diffusion Tensor MR Imaging and Fiber Tractography: Theoretic UnderpinningsAmerican Journal of Neuroradiology, 2008
- Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noiseMagnetic Resonance in Medicine, 2007
- RESTORE: Robust estimation of tensors by outlier rejectionMagnetic Resonance in Medicine, 2005
- POCSENSE: POCS‐based reconstruction for sensitivity encoded magnetic resonance imagingMagnetic Resonance in Medicine, 2004
- Set theoretic compression with an application to image codingIEEE Transactions on Image Processing, 1998
- Analysis and correction of motion artifacts in diffusion weighted imagingMagnetic Resonance in Medicine, 1994