Preventive risk analysis in the maintenance of patency of the peripherally inserted central catheter
Open Access
- 1 January 2019
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Revista da Escola de Enfermagem da USP
- Vol. 53, e03462
Abstract
This theoretical and reflexive study analyzed the risks related to the maintenance of patency of the Peripherally Inserted Central Catheter with the use of saline solution in comparison with saline-filled syringes, through the application of the Healthcare Failure Mode and Effect Analysis - HFMEA. The process was mapped, detailing the failure modes of each step. For the calculation of the Risk Priority Number, the severity and probability of the failure modes were analyzed. This analysis gave rise to the severity and probability matrix. Finally, actions to reduce the failure modes in the maintenance of patency were proposed, considering the use of saline-filled syringes in comparison to the use of saline ampoules. It was verified that the use of saline ampoules is associated with a greater risk, since it requires four stages more than saline-filled syringe does not, increasing the risk of contamination and the level of three different risks, which would result in additional hospital costs. The use of the saline-filled syringe would avoid risks that could negatively affect the patient’s health, the nursing professional and the health institution.Keywords
This publication has 8 references indexed in Scilit:
- Expanding healthcare failure mode and effect analysis: A composite proactive risk analysis approachReliability Engineering & System Safety, 2018
- A comparison of two prospective risk analysis methods: Traditional FMEA and a modified healthcare FMEAMedical Physics, 2016
- Era 3 for Medicine and Health CareJAMA, 2016
- Proactive Risk Assessment of Blood Transfusion Process, in Pediatric Emergency, Using the Health Care Failure Mode and Effects Analysis (HFMEA)Global Journal of Health Science, 2014
- Use of Healthcare Failure Mode and Effect Analysis (HFMEA) to Quantify Risks of the Human Milk Feeding ProcessJournal of Nursing Care Quality, 2014
- The Risk of Bloodstream Infection Associated with Peripherally Inserted Central Catheters Compared with Central Venous Catheters in Adults: A Systematic Review and Meta-AnalysisInfection Control & Hospital Epidemiology, 2013
- Prospective risk analysis of the anti-infective medication administration processRevista Latino-Americana de Enfermagem, 2013
- A systematic review of evidence on the links between patient experience and clinical safety and effectivenessBMJ Open, 2013