Rate of posterior capsule opacification in eyes with the Akreos intraocular lens
Authors:
- Masoud TeimoryMTMasoud Teimory
- 1 August 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (8) , 1409-1413
Abstract
To determine the rate of posterior capsule opacification (PCO) in eyes with an Akreos Adapt or Akreos Fit intraocular lens (IOL) (Bausch & Lomb) over a minimum follow-up of 18 months. Department of Ophthalmology, Worthing and Southlands Hospital NHS Trust, Worthing, United Kingdom. This was a retrospective analysis of 102 patients who had uneventful phacoemulsification with implantation of an Akreos Adapt IOL or Akreos Fit IOL from September 2001 to May 2004. Patients from a single surgeon's operating list were recruited into the study. Exclusion criteria included posterior subcapsular cataract, history of uveitis, diabetic retinopathy, glaucoma, and age-related macular degeneration. The protocol included the determination of logMAR best corrected visual acuity (BCVA) and PCO scoring using the Evaluation of Posterior Capsular Opacification System (EPCO 2000) by digital photography of the posterior capsule. The number of patients having a neodymium:YAG (Nd:YAG) capsulotomy was also recorded. The mean follow-up was 30 months +/- 10.3 (SD). The mean BCVA was 20/32 (0.2 logMAR). The mean EPCO score at the central 6.0 mm of the posterior capsule was 0.39 +/- 0.53 and at the central 3.0 mm, 0.18 +/- 0.40. The Nd:YAG capsulotomy rate was 8.8%. All patients had stable visual acuity with low rates of PCO 2.5 years after surgery. The PCO rate with the Akreos IOL was similar to that with other acrylic IOLs reported in the literature.Keywords
This publication has 15 references indexed in Scilit:
- Influence of 360-degree enhanced optic edge design of a hydrophilic acrylic intraocular lens on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2007
- Complications of foldable intraocular lenses requiring explantation or secondary intervention—2001 survey updateJournal of Cataract & Refractive Surgery, 2002
- Systems of analysis of posterior capsule opacificationBritish Journal of Ophthalmology, 2002
- Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lensesJournal of Cataract & Refractive Surgery, 2002
- Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2002
- 12 year results of a prospective trial comparing poly(methyl methacrylate) and poly(hydroxyethyl methacrylate) intraocular lenses1Journal of Cataract & Refractive Surgery, 1999
- Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsuleJournal of Cataract & Refractive Surgery, 1999
- Quantitative Comparison of Posterior Capsule Opacification After Polymethylmethacrylate, Silicone, and Soft Acrylic Intraocular Lens ImplantationArchives of Ophthalmology (1950), 1998
- Relationship between intraocular lens biomaterials and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1998
- Removal of lens epithelial cells following loosening of the junctional complexJournal of Cataract & Refractive Surgery, 1993