An Evaluation of Hardware and Surgical Complications with Deep Brain Stimulation Based on Diagnosis and Lead Location
Authors:
- Steven FalowskiSFSteven Falowski
- Yinn Cher OoiYOYinn Cher Ooi
- Adam SmithASAdam Smith
- Leonard Verhargen MetmanLMLeonard Verhargen Metman
- Roy A.E. BakayRBRoy A.E. Bakay
- 1 June 2012
- journal article
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 90 (3) , 173-180
Abstract
Introduction: Deep brain stimulation is the most frequently performed neurosurgical procedure for movement disorders. This procedure is well tolerated, but not free of complications. Analysis of hardware complications based on patient diagnosis and lead location could prove valuable in recognizing potential pitfalls and patients at higher risk. Methods: This review analyzes the most common surgery-related complications that may occur based on diagnosis and lead location. Patients were categorized based on diagnosis – Parkinson’s disease (PD), dystonia, and essential tremor (ET) – as well as by lead location – subthalamic nucleus (STN), globus pallidus interna (GPi), and ventral intermediate nucleus of the thalamus (Vim). It is a retrospective review of 326 patients undergoing 949 procedures over a 10-year period by one surgeon. Fisher’s exact test and χ2 test were employed and multivariate logistic regression analysis was performed to identify the significant variables of correlation. Results: Overall lead revision was observed at 5.7%, but was observed at 11.9% of GPi lead placements, and 10.7% of dystonia patients with only 4.6% of STN lead placements. Total extension revision was at 2.5%, but observed at 5.3% for dystonia patients and at only 1.4% for ET patients. Overall infection rate was at 1.9% with the highest rate observed in dystonia and ET patients. Postoperative complications with hardware, erosion, infection, and delayed stimulation failure were observed more often with ET and dystonia than with PD. This difference was statistically significant between dystonia and PD (p < 0.03) but not between the other disease entities (p > 0.05). On multivariate analysis, age and gender had no correlation with these complications. PD had significantly fewer complications on forward selection regression analysis (p = 0.004). Asymptomatic intracerebral hemorrhage was at 2.5% with the majority in Vim and none observed in GPi placements. There was only one symptomatic hemorrhage with a permanent deficit. Infarcts were observed at 0.8%. There were no mortalities. Conclusion: This large series of patients and long-term follow-up demonstrate that risks of complications are not universal among movement disorder patients. Diagnosis and lead location are important risk stratification factors in determining complications.Keywords
This publication has 28 references indexed in Scilit:
- Standard guidelines for publication of deep brain stimulation studies in Parkinson's disease (Guide4DBS‐PD)Movement Disorders, 2010
- Efficacy of Antibiotic Prophylaxis Before the Implantation of Pacemakers and Cardioverter-DefibrillatorsCirculation: Arrhythmia and Electrophysiology, 2009
- Bilateral Deep Brain Stimulation vs Best Medical Therapy for Patients With Advanced Parkinson DiseaseA Randomized Controlled TrialJAMA, 2009
- Deep brain stimulation for Parkinson's disease: Prevalence of adverse events and need for standardized reportingMovement Disorders, 2007
- Incidence of symptomatic hemorrhage after stereotactic electrode placementJournal of Neurosurgery, 2007
- Deep-brain stimulation: long-term analysis of complications caused by hardware and surgery--experiences from a single centreJournal of Neurology, Neurosurgery & Psychiatry, 2006
- Management of hardware infections following deep brain stimulationActa Neurochirurgica, 2004
- Technical Complication in Deep Brain StimulationCentral European Neurosurgery, 2002
- Revision of deep brain stimulator for tremorJournal of Neurosurgery, 2001
- Treatment of Chronic Pain by Deep Brain Stimulation: Long Term Follow-up and Review of the LiteratureNeurosurgery, 1987