Safety and feasibility of the new 5 Fr Glidesheath Slender
Open Access
- 4 July 2015
- journal article
- research article
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 31 (1) , 38-41
Abstract
The aim of this study was to evaluate the safety and feasibility of the new 5 Fr Glidesheath Slender (GSS). The transradial (TR) approach has become popular because of several advantages, such as a reduced rate of vascular access site complications. However, because the radial artery is narrow, a limitation of TR access is the potential for artery spasm or occlusion. Studies of radial artery size demonstrate that 5 Fr sheaths are too wide for more than 10 % of patients. The GSS (Terumo, Tokyo, Japan) is a new radial sheath with a thinner wall and a hydrophilic coating. It has an inner diameter that is compatible with a 5 Fr guiding catheter, while the outer diameter is similar to that of a 4 Fr sheath. A total of 21 consecutive patients undergoing transradial angiography and/or transradial percutaneous coronary intervention with the 5 Fr GSS were included, and safety and feasibility of the device were assessed. Transradial angiography was performed in 10 patients, and transradial intervention in 11 patients. All procedures were successful, without the need for conversion to the transfemoral approach. The radial artery occlusion rate was 0 %, including a patient who had experienced six previous radial artery punctures. There were no cases of artery spasm, hematoma, major bleeding or functional disorders. One coronary artery perforation caused by a guidewire was reported, but it was unrelated to the sheath introducer. The new 5 Fr GSS was safe and feasible for transradial angiography and transradial intervention.Keywords
This publication has 12 references indexed in Scilit:
- Focus on maximal miniaturisation of transradial coronary access materials and techniques by the Slender Club Japan and Europe: an overview and classificationEuroIntervention, 2015
- Initial experience with the glidesheath slender for transradial coronary angiography and intervention: A feasibility study with prospective radial ultrasound follow‐upCatheterization and Cardiovascular Interventions, 2013
- Adoption of Radial Access and Comparison of Outcomes to Femoral Access in Percutaneous Coronary InterventionCirculation, 2013
- Radial Versus Femoral Randomized Investigation in ST-Segment Elevation Acute Coronary SyndromeJACC, 2012
- Analysis of right radial artery for transradial catheterization by quantitative angiography--anatomical consideration of optimal radial puncture point.2010
- A prospective multicenter registry of 0.010‐inch guidewire and compatible system for chronic total occlusion: The PIKACHU registryCatheterization and Cardiovascular Interventions, 2010
- Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: A systematic review and meta-analysis of randomized trialsAmerican Heart Journal, 2009
- A 5Fr Catheter Approach Reduces Patient Discomfort during Transradial Coronary Intervention Compared with a 6Fr Approach: A Prospective Randomized StudyJournal of Interventional Cardiology, 2006
- Definition of major bleeding in clinical investigations of antihemostatic medicinal products in non‐surgical patientsJournal of Thrombosis and Haemostasis, 2005
- A critical review of visual analogue scales in the measurement of clinical phenomenaResearch in Nursing & Health, 1990