Editors' Choice—Review—In Vivo and In Vitro Microneedle Based Enzymatic and Non-Enzymatic Continuous Glucose Monitoring Biosensors
Authors:
Open Access
- 24 April 2018
- journal article
- review article
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 7 (7) , Q3159-Q3171
Abstract
Microneedles have emerged for transdermal monitoring of biomarkers, which are a miniaturized replica of hypodermic needles with length-scales of hundreds of micrometers, with a goal to achieve time-sensitive clinical information for routine point-of-care health monitoring. Transdermal biosensing via microneedles offers remarkable opportunities for moving biosensing technologies from research laboratories to real-field applications and enables development of easy-to-use point-of-care microdevices, minimally invasive, and with minimal-training features that are very attractive for both developed and emerging countries. This would eliminate the need for blood extraction using hypodermic needles and in turn, reduce the related problems such as infections in the patients, sample contaminations, and analysis artifacts. In this review, we provide a general overview of recent progress in microneedle-based sensing research, including: (a) in-vivo microneedle diagnostic systems for glucose monitoring with an emphasis on sensor construction and general health monitoring (b) in-vitro use of microneedle sensors. The main objective of the review is to provide a thorough and critical analysis of recent advances and developments in microneedle research field and to bridge the gap between microneedles and biosensors.Keywords
Funding Information
- National Research Foundation of Korea (NRF) (NRF-2017R1D1A1A9000712)
This publication has 70 references indexed in Scilit:
- Fabrication of a Microneedle/CNT Hierarchical Micro/Nano Surface Electrochemical Sensor and Its In-Vitro Glucose Sensing CharacterizationSensors, 2013
- Multiplexed microneedle-based biosensor array for characterization of metabolic acidosisTalanta, 2012
- Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient dataBMJ, 2011
- Current Application of Continuous Glucose Monitoring in the Treatment of DiabetesDiabetes Care, 2011
- Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 DiabetesDiabetes Care, 2011
- Integrated carbon fiber electrodes within hollow polymer microneedles for transdermal electrochemical sensingBiomicrofluidics, 2011
- Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safetyDrug Delivery, 2010
- 10-Year Follow-up of Intensive Glucose Control in Type 2 DiabetesNew England Journal of Medicine, 2008
- Managing Preexisting Diabetes for PregnancyDiabetes Care, 2008
- Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A1cJAMA, 2006