Abstract
Objectives: This study aimed at assessing the performance of a new generation polymer‐free biolimus‐eluting stent (BES) in real‐world patients with ST‐segment elevation myocardial infarction (STEMI).Background: Polymers components of early‐generation drug‐eluting stents have been implicated in the pathogenesis of delayed arterial healing, vessel remodeling, and delayed stent thrombosis. Recently, a novel polymer‐free BES has shown excellent clinical performance in clinical trial setting.Methods: Overall, 175 consecutive patients (64 ± 14 years, 141 men) treated with the BioFreedom (Biosensors Europe, Morges, Switzerland) polymer‐free BES because of STEMI were included in this study. The primary endpoint was the rate of major adverse cardiac events (MACE), a composite of cardiac death, recurrent myocardial infarction, and ischemia‐driven target vessel revascularization at 1 year follow‐up. A subgroup of patients underwent 6‐month angiographic follow‐up. Dual antiplatelet therapy was prescribed for 12 months after STEMI.Results: At 1 year, the cumulative rate of MACE was 4.6%. One patient (0.6%) had an arrhythmic cardiac death and five (2.9%) had ischemia‐driven target vessel revascularization, although only three (1.7%) had target lesion revascularization. Two (1.1%) patients had acute stent thrombosis yielding nonfatal myocardial infarction. In 70 patients (63 ± 14 years, 61 men), quantitative coronary angiography at 6‐month follow‐up revealed diameter stenosis of 24.1 ± 13.7% and minimal lumen diameter of 2.29 ± 0.56 mm, yielding a late lumen loss of 0.13 ± 0.14 mm.Conclusions: In real‐world setting, implantation of a new‐generation polymer‐free BES during STEMI is associated with favorable clinical and angiographic results, pointing toward the overall efficacy and safety of the device in complex clinical scenarios.Keywords
This publication has 25 references indexed in Scilit:
- The Pathology of Neoatherosclerosis in Human Coronary ImplantsJACC, 2011
- Different Vascular Healing Patterns With Various Drug-Eluting Stents in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction: Optical Coherence Tomographic FindingsThe American Journal of Cardiology, 2010
- Clinical and Angiographic Results With the Next-Generation Resolute Stent SystemJACC: Cardiovascular Interventions, 2009
- Paclitaxel-Eluting Stents versus Bare-Metal Stents in Acute Myocardial InfarctionNew England Journal of Medicine, 2009
- Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosisEuropean Heart Journal, 2009
- Delayed Arterial Healing and Increased Late Stent Thrombosis at Culprit Sites After Drug-Eluting Stent Placement for Acute Myocardial Infarction PatientsCirculation, 2008
- Clinical End Points in Coronary Stent TrialsCirculation, 2007
- Drug-Eluting Stent and Coronary ThrombosisCirculation, 2007
- Pathology of Drug-Eluting Stents in HumansJACC, 2006
- Pathology of the Vulnerable PlaqueJACC, 2006