Glucose absorption and gastric emptying in critical illness
Authors:
- Marianne J ChapmanMCMarianne J Chapman
- Robert Jl FraserRFRobert Jl Fraser
- Geoffrey MatthewsGMGeoffrey Matthews
- Antonietta RussoARAntonietta Russo
- Max BellonMBMax Bellon
- Laura K BesankoLBLaura K Besanko
- Karen L JonesKJKaren L Jones
- Ross ButlerRBRoss Butler
- Barry ChattertonBCBarry Chatterton
- Michael HorowitzMichael Horowitz
Open Access
- 27 August 2009
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 13 (4) , R140
Abstract
Introduction: Delayed gastric emptying occurs frequently in critically ill patients and has the potential to adversely affect both the rate, and extent, of nutrient absorption. However, there is limited information about nutrient absorption in the critically ill, and the relationship between gastric emptying (GE) and absorption has hitherto not been evaluated. The aim of this study was to quantify glucose absorption and the relationships between GE, glucose absorption and glycaemia in critically ill patients. Methods: Studies were performed in nineteen mechanically-ventilated critically ill patients and compared to nineteen healthy subjects. Following 4 hours fasting, 100 ml of Ensure, 2 g 3-O-methyl glucose (3-OMG) and 99mTc sulphur colloid were infused into the stomach over 5 minutes. Glucose absorption (plasma 3-OMG), blood glucose levels and GE (scintigraphy) were measured over four hours. Data are mean ± SEM. A P-value < 0.05 was considered significant. Results: Absorption of 3-OMG was markedly reduced in patients (AUC240: 26.2 ± 18.4 vs. 66.6 ± 16.8; P < 0.001; peak: 0.17 ± 0.12 vs. 0.37 ± 0.098 mMol/l; P < 0.001; time to peak; 151 ± 84 vs. 89 ± 33 minutes; P = 0.007); and both the baseline (8.0 ± 2.1 vs. 5.6 ± 0.23 mMol/l; P < 0.001) and peak (10.0 ± 2.2 vs. 7.7 ± 0.2 mMol/l; P < 0.001) blood glucose levels were higher in patients; compared to healthy subjects. In patients; 3-OMG absorption was directly related to GE (AUC240; r = -0.77 to -0.87; P < 0.001; peak concentrations; r = -0.75 to -0.81; P = 0.001; time to peak; r = 0.89-0.94; P < 0.001); but when GE was normal (percent retention240 < 10%; n = 9) absorption was still impaired. GE was inversely related to baseline blood glucose, such that elevated levels were associated with slower GE (ret 60, 180 and 240 minutes: r > 0.51; P < 0.05). Conclusions: In critically ill patients; (i) the rate and extent of glucose absorption are markedly reduced; (ii) GE is a major determinant of the rate of absorption, but does not fully account for the extent of impaired absorption; (iii) blood glucose concentration could be one of a number of factors affecting GE.Keywords
This publication has 52 references indexed in Scilit:
- Intensive Insulin Therapy in the Medical ICUNew England Journal of Medicine, 2006
- Labeled acetate to assess intestinal absorption in critically ill patientsCritical Care Medicine, 2003
- Induced-Hyperglycemia Attenuates Erythromycin-Induced Acceleration of Hypertonic Liquid-Phase Gastric Emptying in Type-I Diabetic PatientsDigestive Diseases, 1999
- Impaired gastric emptying in mechanically ventilated, critically ill patientsIntensive Care Medicine, 1996
- Gender-related differences in gastric emptying rate of solid mealsDigestive Diseases and Sciences, 1996
- SEVERE DEPRESSION OF GUT ABSORPTIVE CAPACITY IN PATIENTS FOLLOWING TRAUMA OR SEPSIS1994
- Comparison of Left Anterior Oblique, Anterior, and Geometric Mean Methods in Gastric Emptying Assessment of Postpancreaticoduodenectomy PatientsClinical Nuclear Medicine, 1993
- The Association of Age with Gastric EmptyingAge and Ageing, 1993
- Effect of age on gastric emptying of liquid-solid meals in manDigestive Diseases and Sciences, 1983
- Differences between Capillary and Venous Blood Glucose during Oral Glucose Tolerance TestsScandinavian Journal of Clinical and Laboratory Investigation, 1976