Novel integrated paired emitter-detector diode (PEDD) as a miniaturized photometric detector in HPLC
- 20 June 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 131 (8) , 938-943
Abstract
A novel low power, low cost, highly sensitive, miniaturized light emitting diode (LED) based flow detector has been used as optical detector for the detection of sample components in high performance liquid chromatography (HPLC). This colorimetric detector employs two LEDs, one operating in normal mode as a light source and the other is reverse biased to work as a light detector. Instead of measuring the photocurrent directly, a simple timer circuit is used to measure the time taken for the photocurrent generated by the emitter LED (λmax 500 nm) to discharge the detector LED (λmax 621 nm) from 5 V (logic 1) to 1.7 V (logic 0) to give digital output directly without using an A/D converter. Employing a post-column reagent method, a Nucleosil 100-7 column (functionalised with iminodiacetic acid (IDA) groups) was used to separate a mixture of transition metal complexes, manganese(II) and cobalt(II) in 4-(2-pyridylazo)-resorcinol (PAR). All optical measurements were taken by using both the in-built HPLC variable wavelength detector and the proposed paired-emitter-detector-diode (PEDD) optical detector configured in-line for data comparison. The concentration range investigated using the PEDD was found to give a linear response to the Mn(II) and Co(II) PAR complexes. The effects of flow rate and emitter LED light source intensity were investigated. Under optimised conditions the PEDD detector offered a linear range of 0.9–100 µM and LOD of 0.09 µM for Mn–PAR complex. A linear range of 0.2–100 µM and LOD of 0.09 µM for Co–PAR complex was achieved.Keywords
This publication has 27 references indexed in Scilit:
- A new electro-osmotic pump based on silica monolithsSensors and Actuators B: Chemical, 2006
- Development of miniaturized multi-channel high-performance liquid chromatography for high-throughput analysisJournal of Chromatography A, 2005
- Peer Reviewed: Internet-Scale Sensing2004
- Rapid, low pressure, and simultaneous ion chromatography of common inorganic anions and cations on short permanently coated monolithic columnsJournal of Separation Science, 2004
- Performance and reliability of splitless microliter gradient pumps in a metabolic stability study using cytochrome P450/3A4 and capillary liquid chromatography-mass spectrometry.Journal of Chromatography A, 2003
- Progress in the realisation of an autonomous environmental monitoring device for ammoniaTrAC Trends in Analytical Chemistry, 2002
- Micro-HPLC and standard-size HPLC for the separation of peptide stereoisomers employing an ion-exchange principleJournal of Pharmaceutical and Biomedical Analysis, 2002
- An integrated micro ion-exchange separator and detector on a silicon waferChemical Engineering Science, 2001
- Synthesis of spherical porous silicas in the micron and submicron size range: challenges and opportunities for miniaturized high-resolution chromatographic and electrokinetic separationsJournal of Chromatography A, 2000
- Miniaturized HPLC and ionspray mass spectrometry applied to the analysis of Paclitaxel and taxanesJournal of Pharmaceutical and Biomedical Analysis, 1997