Quantification method for elemental bio-imaging by LA-ICP-MS using metal spiked PMMA films
- 14 January 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (5) , 722-725
Abstract
A method for quantitative analysis of biological soft tissues by laser ablation-inductively coupled plasma-mass spectrometry has been developed. Polymer film standards were produced by spin coating spiked solutions of polymethylmethacrylate onto quartz substrates. Calibration curves throughout the range of 0–400 μg g−1 yielded correlation coefficients better than 0.999 for 66Zn and 63Cu. Spiked, homogenised soft tissue standards were quantified by LA-ICP-MS against the thin film standards. The results agreed with values calculated from solution nebulisation ICP-MS. A procedure for internal standardisation by employing ruthenium or yttrium in the underlying thin film was also assessed.Keywords
This publication has 39 references indexed in Scilit:
- Quantitative elemental bio-imaging of Mn, Fe, Cu and Zn in 6-hydroxydopamine induced Parkinsonism mouse modelsMetallomics, 2009
- Quantitative Imaging of Selenium, Copper, and Zinc in Thin Sections of Biological Tissues (Slugs−Genus Arion) Measured by Laser Ablation Inductively Coupled Plasma Mass SpectrometryAnalytical Chemistry, 2007
- Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in elemental imaging of biological tissues and in proteomicsJournal of Analytical Atomic Spectrometry, 2007
- Optical and Redox Properties of Ruthenium Phthalocyanine Complexes Tuned with Axial Ligand SubstituentsInorganic Chemistry, 2007
- A quantification strategy in laser ablation ICP-MS based on the transported aerosol particle volume determined by optical particle size measurementJournal of Analytical Atomic Spectrometry, 2006
- 6 Studies of spin-coated polymer filmsAnnual Reports Section "C" (Physical Chemistry), 2005
- Imaging of Copper, Zinc, and Other Elements in Thin Section of Human Brain Samples (Hippocampus) by Laser Ablation Inductively Coupled Plasma Mass SpectrometryAnalytical Chemistry, 2005
- Direct impurity analysis of semiconductor photoresist samples with laser ablation ICP-MSJournal of Analytical Atomic Spectrometry, 2002
- Calibration of Laser Ablation Inductively Coupled Plasma Mass Spectrometry Using Standard Additions with Dried Solution AerosolsAnalytical Chemistry, 1998
- In-line mass transport measurement cell for improving quantification in sulfide mineral analysis using laser ablation inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1998